On-site elevation of a renovated residential floor with fully installed UPVC windows
Renovation acceptance starts on site: a completed window installation across one residential floor.

Renovation work compresses the specification stage. The window schedule usually has to be approved while the existing building is still being measured, frames are ordered before every reveal has been opened up, and each added requirement moves both cost and delivery. The practical sequence is to separate three decisions: match the model to the site, write only the requirements the project can justify, and agree the acceptance evidence before production begins.

This guide applies that sequence to four models from Foshan Nanhai Yuanzhaiji UPVC Door & Window Factory, a UPVC door and window manufacturer established in 2009 whose range covers sliding, casement, tilt-and-turn, crank awning, American-style hung, awning and hopper windows, insect screens and louver windows, plus UPVC door series. The models in scope are UPVC Window 7970, which the factory lists for renovation projects with manual opening and closing and with optional fire resistance, and the door models HF60, WYK75-1 and HF88-L, which are also used on renovation work. Orders discussed here are settled by bank transfer, and acceptance is handled either through pre-shipment photographs or an on-site inspection.

Why the order, not the installation, decides a renovation

In a new build, the facade is designed as a system and the window order follows a fixed schedule. A renovation inherits the opposite: openings that are out of tolerance, window and door positions mixed inside one contract, and phased site access that forces partial decisions. The specification therefore has to be robust to site reality rather than perfect on paper.

The factory's stated commercial parameters show why an improvised order is expensive to correct. Minimum order quantity is 30–40 m², production lead time is 10–30 days, and monthly capacity is 4,000 m². A missing or wrongly specified item cannot be absorbed by a quick top-up; it becomes a new production slot and a new delivery window. That is the argument for settling the model, the requirement list and the acceptance route together, before the first invoice is raised.

Over-specification is the quieter failure. Adding fire resistance where no compartment requirement exists, pushing the glass build beyond the noise or thermal target, or naming a door model by number without stating the leaf size all add cost and inspection work without adding performance the building can use. The rule used throughout this guide is simple: state the requirement, name the evidence that will prove it, and delete anything that has neither a code driver nor a site driver.

The four models: documented facts and open questions

The table separates what the available model data states from what the purchase order has to establish. Where a cell says “confirm”, the item is a question for the supplier. A blank is not evidence that a model lacks a capability, and it should never be read as a negative rating.

Table 1 — Model scope, documented facts and items to confirm before ordering
ModelProduct role in this guideDocumented applicationDocumented operationDocumented special requirementsTo confirm on the order
7970UPVC windowRenovation projectsManual opening and closingOptional fire resistance; UV resistance and anti-aging listed as requirementsWhether fire resistance is required; size; glass build; site performance values
HF60UPVC doorRenovation work, same factory rangeConfirm on model data sheetConfirm on model data sheetLeaf size, glazing or panel, hardware, threshold, finish
WYK75-1UPVC doorRenovation work, same factory rangeConfirm on model data sheetConfirm on model data sheetLeaf size, glazing or panel, hardware, threshold, finish
HF88-LUPVC doorRenovation work, same factory rangeConfirm on model data sheetConfirm on model data sheetLeaf size, glazing or panel, hardware, threshold, finish

Two readings of the table matter. First, 7970 is the only model here with a documented operation mode and a documented special requirement, so it carries most of the technical decision. Second, the three door models differ by position rather than by a documented rating in the material available: their operation, leaf limits and performance values have to come from the model data sheet issued with the quotation. Treating the numbers inside HF60, WYK75-1 or HF88-L as a performance grade is not supported by the model data.

A practical habit for contractors: keep one column per model in the enquiry spreadsheet and leave nothing blank. A cell that reads “confirm with factory” is acceptable on day one; a cell that is empty at purchase-order stage is a defect waiting to be discovered on site.

When UPVC Window 7970 is the right window specification

7970 fits a renovation window position when three conditions hold at once: the window is operated by hand, the elevation is exposed enough that UV resistance and anti-aging matter, and fire resistance is either not required or is deliberately ordered as the model's optional feature.

Condition 1 — manual operation is the real requirement

Manual opening and closing is the documented operation mode for 7970. That suits renovation work because it removes dependency on actuators and controls in a building whose power and access routes are often being reworked, and because it keeps the operating interface familiar to occupants and maintenance staff. It also sets the boundary: if a position needs sliding, tilt-and-turn or projecting operation, the answer is a different model from the factory's window range, not a modified 7970.

Condition 2 — the elevation is exposed

The factory lists UV resistance and anti-aging performance among the special requirements for 7970. In practice that is the point to check when a renovation enlarges glazing on a sun-facing elevation, or when the original frames failed by yellowing and embrittlement rather than by mechanical damage. Where profile quality is the concern, the relevant reference is GB/T 8814-2017 for unplasticized polyvinyl chloride profiles, which addresses wall thickness, impact resistance, heat stability and anti-aging performance, and which expects supporting test reports rather than a verbal assurance.

Condition 3 — fire resistance is a decision, not a default

Fire resistance is optional on 7970. If the position sits on a compartment line or an escape route and the local building rules demand a rating, the requirement must be written on the order and matched to documentation the supplier can issue for that configuration. If no such rule applies, adding the option increases cost and inspection work for performance the project cannot use. The same logic applies to any value copied in from another project: put the site's required figure in the enquiry and ask for test evidence, instead of accepting a generic description.

For coastal high-humidity or strong-wind sites, the factory's application data lists wind-pressure resistance, water tightness, air permeability, sound and heat insulation, UV resistance and anti-aging, optional fire resistance, and compliance with local building codes as the special requirements for its window applications. Use that list as the agenda for the enquiry. The model data used for this guide does not state 7970's performance classes, so the values have to be confirmed against the project's required figures rather than assumed from the model name.

Choosing among HF60, WYK75-1 and HF88-L

The three door models are alternatives within one UPVC door range, so selection is driven by the door position — leaf size, glazing or panel, traffic, hardware and threshold — and not by which window model was chosen for the same building.

A workable order of decisions is: fix the opening and the leaf; decide whether the door is fully glazed, part-glazed or panelled; list the hardware the position needs; confirm whether a threshold is acceptable at that location; then ask which of HF60, WYK75-1 or HF88-L covers that combination. The reverse order — choosing a model first and forcing the opening to fit it — is where renovation schedules usually break, because the existing structural opening is the one variable that cannot be re-engineered cheaply.

What the available data does and does not settle: the model list used here identifies HF60, WYK75-1 and HF88-L as door models applied to renovation work, but it does not state their operation type, leaf limits, glazing options or thermal values. Those items belong on the model data sheet that accompanies the quotation, together with the hardware schedule. If a door sits on an escape route, the relevant fire or smoke evidence for that specific model should be requested at the same time, not after the frames have been produced.

75-series UPVC half-glazed half-panel casement door for renovation door positions
A 75-series UPVC half-glazed half-panel casement door from the factory's door range; the exact model and configuration must be confirmed against the approved door schedule.

Finish is a separate conversation from model selection. The factory states that it supplies Conch profiles in 60, 65 and 88 series in co-extruded colour, laminated wood-grain finish and solid colours including dark grey and black. Profile supply is not the same as the finish applied to a specific door model, so colour and surface for each door should be confirmed on the order drawing together with the hardware finish.

Writing the order: what each line has to contain

A renovation order mixes window and door positions, so every line has to be readable on its own. The fields below are the minimum set that keeps production, payment and acceptance aligned.

  • Opening reference. Room, elevation and drawing number for each unit, so that a photographed or inspected item can be traced back to a position in the building.
  • Model name. 7970, HF60, WYK75-1 or HF88-L, written exactly and never abbreviated on the order.
  • Size. Width, height and reveal depth for each opening. The factory's customization scope covers window size and specification, so non-standard renovation openings are a specification task rather than an exception.
  • Operation. Manual opening and closing for 7970; for a door model, the confirmed operation taken from its data sheet.
  • Glass. Single-layer, double-glazed insulated, tempered or frosted — one stated choice per position, with the reason recorded against the acoustic or thermal target.
  • Hardware. Handles, hinges, lock points, multipoint lock drive mechanism, crescent lock, rollers, EPDM sealing gasket and pile weather strip are the supporting items listed for the factory's window applications; the schedule should state which of them apply, and where.
  • Fire resistance. Written as required or not required against every 7970 position, with the code reference if required.
  • Finish. Colour and surface per model.
  • Marking. A label per unit matching the opening reference, agreed with the packing list.
  • Documents. Quality Inspection Report, plus CE and ISO certificates as required for the destination market.
  • Commercial terms. Quantity in m² or units against the 30–40 m² minimum, with the 10–30 day lead time planned into the site programme.

Two fields are routinely left blank and cause most of the disputes later: the fire-resistance line and the marking scheme. Both cost nothing to decide at enquiry stage and are difficult to correct once production has started.

Paying by bank transfer

Bank transfer is the settlement route for these orders, and it works best when the proforma invoice is treated as part of the technical file rather than as an administrative afterthought. It should carry the beneficiary name exactly as the contracting entity, the bank name and address, account number, SWIFT or BIC, currency, amount, invoice number, and a model and quantity list that matches the approved order. The documents to be issued — the Quality Inspection Report, certificate copies where required, and the packing list — belong on the same document set.

Verify the account details through a channel you already held before the order, such as the phone number published on the company website or a known contact, rather than through an email that introduces new bank details. Keep the transfer reference identical to the invoice number and file the bank receipt together with the inspection report and the pre-shipment photographs. Where the agreed terms split payment, the balance is easiest to release against acceptance evidence that was defined before production rather than negotiated after it.

Acceptance: pre-shipment photographs or on-site inspection

Two acceptance routes are practical for renovation orders, and either works if the evidence list is agreed in advance. Pre-shipment photographs catch production errors while they can still be corrected at the factory; on-site inspection catches transport damage, installation error and building tolerance problems that no factory photograph can reveal.

Route A — the pre-shipment photo set

  • Every unit labelled with its opening reference, photographed as a group and individually.
  • A dimension check against the approved schedule with the tape or rule visible in the frame.
  • Welded corners, surface finish and colour against the approved sample.
  • Hardware fitted per schedule: handles, hinges, lock points, crescent lock, rollers.
  • Glass type identifiable from marking or spacer, matching the stated build.
  • Gaskets and weather strips in place along the full perimeter.
  • Packing, protection and loading arrangement before the container is closed.

The factory states its quality control output as a Quality Inspection Report, and the photo set should be read against that report rather than on its own.

Route B — on-site inspection

On site, the checks are operation, alignment, sealing, drainage and damage. A sash that is stiff or hard to move is one of the most common early complaints, and the factory's troubleshooting guidance traces it to three causes: debris or dust in the track, a worn or displaced pulley, and hardware that is out of adjustment. The matching remedies are to clean the track, replace a worn pulley, and adjust the hinge or roller screw to level the sash. Recording these at handover separates a normal installation adjustment from a genuine product fault.

Field-installed UPVC sliding window inspected on site after installation
A field-installed unit from a completed project: on-site inspection checks operation, alignment, sealing and drainage rather than appearance alone.

What a photograph cannot prove

Photographs show geometry, finish and hardware presence; they do not prove profile wall thickness, formulation or thermal performance. Those come from test reports. The factory's published material values for its UPVC window range — Vicat softening point 86 °C, flexural modulus of elasticity 2,840 MPa, tensile yield stress 43 MPa, tensile strain at break 186% and density 1,520 kg/m³ — are useful only if they are matched to the profile actually quoted for the project. Where Conch profiles are specified, confirm the genuine supply source, because counterfeit profile carries the same yellowing and air-leakage risks as low-grade material.

Compliance values must also match the destination market. In England and Wales, for example, the legal whole-window U-value limit for window replacement in existing homes is 1.4 W/m²K in 2025 under Approved Document L, so acceptance there has to include the corresponding test evidence rather than a visual check. In markets without a stated limit in this guide, the project's own specification takes that role.

Scenario fit: three renovation situations

Sun-exposed residential refurbishment with heat and noise targets

A builder client in Kenya used the factory's UPVC windows on a residential project of 800 m², with heat insulation and noise reduction as the stated requirement. The reported outcome was heat-insulation and sound-insulation performance, with energy-saving performance reported for the installed windows. That is one documented project and not a guarantee for a different building; the transferable part is the method — state the heat and noise target, select frame and glass against it, and record the evidence that proves it.

Coastal high-humidity refurbishment

Coastal high-humidity and strong-wind conditions lengthen the requirement list: wind-pressure resistance, water tightness, air permeability, sound and heat insulation, UV resistance and anti-aging, optional fire resistance, and compliance with local building codes. Renovation adds a constraint, because new frames have to suit existing reveals and fixing positions. Put the site's figures into the enquiry, ask for the test values that sit behind them, and keep 7970's optional fire resistance as its own line rather than folding it into a general performance statement.

Mixed window and door replacement in one contract

When a renovation replaces windows and doors together, the door positions are usually the smaller share of the order and the easiest to under-specify. Give each HF60, WYK75-1 or HF88-L position the same treatment as a window: opening reference, leaf size, glazing or panel, hardware, threshold, finish, and any fire or smoke evidence. A door ordered from a model number alone is the item most likely to be remade.

The supply context is also worth knowing. Foshan Nanhai is a recognised manufacturing base for UPVC profiles and windows, and an industry publication estimates a 30–40 year lifespan for high-quality profiles from the cluster. That is a third-party estimate for a material category, not a warranty on any model, and it explains why profile and formulation checks during acceptance are worth the effort. The factory reports that 80% of its output is exported to Latin America, the Middle East, ASEAN and the EU, which is a useful indication of where its documentation is normally read.

Over-specification check before the enquiry goes out

  • Is fire resistance required by the project's code path, or is it being added by default to 7970?
  • Does any window position genuinely need an operation mode other than manual opening and closing?
  • Is the glass build justified by a noise or heat target, or copied from an earlier project?
  • Does each door model match its leaf, traffic and hardware, or was it copied from the window schedule?
  • Is the acceptance route — photographs or on-site inspection — agreed before production rather than after?
  • Are the bank details verified through an independent channel, and does the proforma match the approved order line by line?

Conclusion

For a renovation project, UPVC Window 7970 is the specification to use when a window position is manually operated, exposed to sunlight, and either does not need fire resistance or needs it as an explicitly ordered option. The door models HF60, WYK75-1 and HF88-L belong to the same renovation package but not to the same decision: each is selected from its own data sheet against leaf size, glazing or panel, hardware and threshold. Keeping those two decisions apart is what prevents a single model number from being stretched across positions it was never documented for.

The order and acceptance sequence is what makes the choice usable. A line-by-line schedule, a proforma invoice that matches it, bank details verified independently, and a photo or on-site acceptance list agreed in advance turn a renovation order into something a contractor can defend to a client. Where a value is missing, the correct move is to ask for it and record the answer, not to fill the gap with an assumption.

To match models to a live renovation schedule, Foshan Nanhai Yuanzhaiji UPVC Door & Window Factory accepts opening schedules with model, size, glass, hardware and fire-resistance requirements, and can support the review with samples and technical consultancy. Company details are published at yuanzhaiji.com.

FAQ

Is fire resistance standard on UPVC Window 7970?

No. Fire resistance is an optional special requirement on 7970, not a default feature. If the window position is on a compartment line or escape route and local building rules demand a rating, the requirement has to be written on the order and supported by documentation for that configuration. If no rule applies, the option can be omitted, which keeps cost and inspection work aligned with what the building actually needs.

What operation mode does 7970 use, and where does that limit it?

7970 operates in manual opening and closing mode and is listed by the factory for renovation projects. That covers hand-operated replacement windows, including sun-exposed elevations where UV resistance and anti-aging are listed requirements. It does not cover positions that need sliding, tilt-and-turn or projecting operation; those are served by other models in the factory's window range and should be raised as a separate model question.

Can HF60, WYK75-1 and HF88-L be used in the same renovation as 7970 windows?

They can be part of the same renovation package. HF60, WYK75-1 and HF88-L are UPVC door models in the same factory range and are also applied to renovation work, while 7970 covers the window positions. Each door still needs its own data sheet, leaf size, glazing or panel choice, hardware schedule and threshold decision, and the operating and performance values of the window model should not be assumed to transfer to the doors.

What should acceptance include for these models?

Acceptance uses one of two routes, or both: a pre-shipment photo set covering labels, dimensions, corners, hardware, glass identification, gaskets and packing, read against the Quality Inspection Report; or an on-site inspection covering operation, alignment, sealing, drainage and transit damage, with stiff sashes traced to track debris, a worn pulley or hardware adjustment. Profile claims need test reports, including GB/T 8814-2017 evidence on wall thickness, impact resistance, heat stability and anti-aging, and any code-driven value such as a whole-window U-value limit.

What are the minimum order quantity and production capacity?

The stated minimum order quantity is 30–40 m², with monthly capacity of 4,000 m² and OEM, ODM and customization available for window size, specification and glass specification. Because the minimum is expressed in area, a small late addition to a renovation package is inefficient; grouping window and door positions into one schedule is usually the better approach. Prices are not published in this guide and are quoted against the actual schedule.

Can samples be reviewed before the full order?

Yes. The factory states that a sample showroom is available for one-stop purchasing, and after-sales support covers technical consultancy and quality testing. For a renovation, a sample review is most useful when it is matched to the profile, colour and hardware proposed for the project, so the sample discussion should reference the opening schedule rather than a generic catalogue page.

How long does production take, and how does a contractor start?

Lead time is 10–30 days, counted from a confirmed order rather than from the first enquiry. The fastest route is to send the opening schedule with model names, sizes, glass and hardware choices, fire-resistance status for each 7970 position, required test values and the preferred acceptance route; the factory can then return a quotation, a data sheet per model and a sample proposal for review. Orders are settled by bank transfer, with account details verified independently before payment.

Have Questions or Need More Details?

Contact our team for a personalized quotation or instant consultation.

Request a Quotation

Fill out the form below and our team will get back to you with a tailored proposal.

Attach images, files, or documents.

We'll respond within 24 hours (Mon–Sat).

WhatsApp Direct Chat

Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.

  • Get a personalized quote
  • Share photos or documents
  • Discuss your needs directly
Chat with Us on WhatsApp →