🌍 GRT Relay Since 2003 ⭐ 23+ Year Industry Experience ✓ Verified Elite Supplier
✓ Verified Elite Supplier
Menu

1-Pole vs 2-Pole Latching Relays for Meter Switching: A Side-by-Side Comparison

Author: GRT Relay Release time: 2026-10-24 05:20:35 View number: 56

GRT508BG 1-pole latching relay, 90 A contact switching, PCB soldering type for smart meter switching
GRT508BG: 1-pole latching relay, 90 A resistive rating, PCB soldering, 38 × 30 × 16.5 mm.

The short answer: pole count changes how many separate circuits one coil pulse switches, not how much current a single contact can carry. In GRT Relay's metering range, GRT508BG is the 1-pole reference at 90 A with PCB soldering and a 38 × 30 × 16.5 mm footprint, while GRT508BJ (90 A, 64 × 36.5 × 18.3 mm), GRT508BV (80 A listed, 52.5 × 35 × 17.7 mm) and GRT508BW (80 A listed, 55.6 × 30 × 16.5 mm) are 2-pole units with fast-connection terminals. All four share a 250 VAC maximum switching voltage, a 5–24 VDC coil range, AgSnO2 contacts and 4 kV dielectric strength between coil and contacts. What separates them is footprint, terminal style, listed endurance and the certification evidence available per model.

Why pole count is a constraint problem, not a preference

Buyers rarely choose between one and two poles on taste. They choose because their meter design has already fixed three things: how many circuit paths must be opened, how much copper and terminal hardware fits inside the enclosure, and which conformity documents the destination market accepts. Once those three are fixed, the pole decision is usually forced.

Three failure patterns show up repeatedly when a 1-pole vs 2-pole decision is made on the relay nameplate alone:

  • Paying area for a pole you do not switch. A 2-pole unit is larger than a 1-pole unit in the same family. GRT508BJ occupies 64 × 36.5 mm, roughly 2.05 times the board area of the 38 × 30 mm GRT508BG, before any terminal or wire clearance is added.
  • Breaking only the line when the application expects both conductors to open. Pole count is a functional property; it cannot be compensated later with wiring inside a sealed meter.
  • Treating a compliance statement as a certificate. A product page can state IEC 62055-31 UC2 compliance while the certificate record is issued for a different model in the family. Qualification teams need the document, not the adjective.
One specification conflict worth resolving before quoting:GRT508BV is listed with a rated resistive load of 80 A and a maximum switching current of 80 A, while the stated feature line for the same model reads 60 A contact switching capability, and its product image set is labelled 2 × 60 A. GRT508BJ, by contrast, is consistently listed at 90 A rated load, 90 A maximum switching current and 90 A contact switching capability. When a variant matters, state the exact current on the RFQ rather than the model name alone.

Industry background: what a latching relay must satisfy inside a meter

A latching relay is a bistable device. The contact position is held by a permanent magnet, so the coil needs only a pulse to change state and no continuous supply to stay there. That is the engineering reason latching relays are specified in metering: switching happens on command, but holding consumes nothing. GRT describes its latching relays as pulse-excited for both single-coil and double-coil versions, and the feature is listed explicitly in the GRT508BW data.

Compliance for this component is layered rather than singular, which is why a single certificate rarely closes a metering project:

  • General relay safety. IEC 61810-1 covers general and safety requirements for electromechanical elementary relays. EN 61810-1:2015+A1:2020 is the harmonised version referenced in European CE certificates, including the GRT508BW certificate.
  • Application-level metering. IEC 62055-31 addresses payment metering systems and defines utilisation categories — UC2, UC3 and UC4 — used to describe load switching capability, short-circuit current carrying capacity and fault current making for relays in payment meters.
  • Horizontal regulation. Directive 2011/65/EU (RoHS 2) restricts hazardous substances in electrical and electronic equipment placed on the EU market, which is why RoHS statements appear on every model in this comparison.

Trade classification adds a further wrinkle. Relays fall under HS heading 8536, split into 8536.41 (voltage not exceeding 60 V) and 8536.49 (other). There is no dedicated HS code for latching relays, so public trade statistics cannot isolate this product family — a point worth remembering when a supplier presents import volumes as evidence of category demand.

The four models in this comparison

All four products below are classified as latching relays for the smart metering industry, with smart meter, prepaid meter and smart home switching listed among the typical application scenarios. Each uses AgSnO2 contacts, copper and plastic construction, and is rated for an ambient temperature range of -40 °C to +85 °C.

GRT508BG — the 1-pole, PCB-soldering reference

GRT508BG is a 1-pole latching relay rated 90 A resistive at a maximum switching voltage of 250 VAC, with a coil range of 5–24 VDC and mechanical endurance of 100,000 operations. Maximum short-circuit current is stated as 2500 A/10 ms and 4500 A/10 ms without explosion. Installation is PCB soldering, and the outline is 38 × 30 × 16.5 mm — the smallest envelope in this group. It carries 4 kV dielectric strength between coil and contacts, is RoHS compliant, and is described as IEC 62055-31 UC2 compliant.

GRT508BJ 2-pole latching relay, 2 x 90 A, fast connection terminals for smart meter
GRT508BJ: 2-pole latching relay, 90 A resistive rating, fast connection, 64 × 36.5 × 18.3 mm.

GRT508BJ — 2-pole, 90 A, fast connection

GRT508BJ keeps the 90 A resistive rating and the 250 VAC maximum switching voltage of the 1-pole model but switches two circuits. Coil range is 5–24 VDC, mechanical endurance is 100,000 operations, and maximum short-circuit current matches GRT508BG at 2500 A/10 ms and 4500 A/10 ms without explosion. The data lists a T1 in and T4 out design and custom assemblies with flexible wire, copper straps and/or an integrated shunt. Installation is fast connection; the outline is 64 × 36.5 × 18.3 mm, the largest in this group.

GRT508BV 2-pole latching relay with fast connection terminals, T1 in and T4 out design
GRT508BV: 2-pole latching relay, 80 A listed resistive rating with 60 A contact switching capability stated, 52.5 × 35 × 17.7 mm.

GRT508BV — 2-pole, 80 A listed, UC2 certificate on record

GRT508BV is listed at 80 A resistive with an 80 A maximum switching current at 250 VAC, a 5–24 VDC coil and 100,000 mechanical operations. Its stated feature line is 60 A contact switching capability, and the product image set is labelled 2 × 60 A — so the current rating is the one item to confirm in writing. It also lists a T1 in and T4 out design, 4 kV dielectric strength, RoHS compliance and IEC 62055-31 UC2 compliance, with fast-connection terminals and a 52.5 × 35 × 17.7 mm outline. Uniquely in this group, it has a named third-party certificate: UC2 safety certification AK 50686063 0001 issued by TUV Rheinland for the EU market, listing EN 62052-31:2016 and IEC 62052-31:2015.

GRT508BW 2-pole latching relay, 80 A, compact 55.6 x 30 x 16.5 mm housing
GRT508BW: 2-pole latching relay, 80 A resistive rating, 55.6 × 30 × 16.5 mm, CE certified to EN 61810-1:2015+A1:2020.

GRT508BW — 2-pole, 80 A listed, endurance and CE on record

GRT508BW is listed at 80 A resistive, 80 A maximum switching current, 250 VAC maximum switching voltage and a 5–24 VDC coil. It is the only model in this comparison with an electrical endurance figure in its data: 10,000 operations, alongside 100,000 mechanical operations and a short-circuit rating of 2500 A/10 ms and 4500 A/10 ms without explosion. It specifies pulse excitation for both single-coil and double-coil versions, low power consumption, custom assemblies with flexible wire, copper straps and/or an integrated shunt, and 4 kV dielectric strength. Installation is fast connection at 55.6 × 30 × 16.5 mm — the smallest 2-pole envelope here. Its CE certificate TTC-23-1307/02/02 was issued by INTEGRA96 against EN 61810-1:2015+A1:2020 and IEC 61000-6-1:2019, valid from 2023-07-13 to 2028-07-13 for the EU market. The product image set covers 2 × 80 A, 2 × 90 A and 2 × 100 A pole configurations, so the exact variant should be fixed on the purchase order.

Side-by-side specification table

ParameterGRT508BG
(1-pole)
GRT508BJ
(2-pole)
GRT508BV
(2-pole)
GRT508BW
(2-pole)
Rated load (resistive)90 A90 A80 A80 A
Max. switching current90 A90 A80 A80 A
Stated contact switching capability90 A90 A60 A80 A
Max. switching voltage250 VAC250 VAC250 VAC250 VAC
Coil voltage5–24 VDC5–24 VDC5–24 VDC5–24 VDC
Contact materialAgSnO2AgSnO2AgSnO2AgSnO2
Mechanical endurance100,000 OPS100,000 OPS100,000 OPS100,000 OPS
Electrical enduranceNot listed in product dataNot listed in product dataNot listed in product data10,000 OPS
Max. short-circuit current2500 A/10 ms and 4500 A/10 ms (no explosion)2500 A/10 ms and 4500 A/10 ms (no explosion)2500 A/10 ms and 4500 A/10 ms (no explosion)2500 A/10 ms and 4500 A/10 ms (no explosion)
Dielectric strength, coil to contact4 kV4 kV4 kV4 kV
Ambient temperature-40 °C to +85 °C-40 °C to +85 °C-40 °C to +85 °C-40 °C to +85 °C
Installation formPCB solderingFast connectionFast connectionFast connection
Outline dimensions38 × 30 × 16.5 mm64 × 36.5 × 18.3 mm52.5 × 35 × 17.7 mm55.6 × 30 × 16.5 mm
Footprint area (from listed dimensions)1,140 mm²2,336 mm²1,837.5 mm²1,668 mm²
Footprint area per pole1,140 mm²1,168 mm²918.75 mm²834 mm²
Listed design attributePCB soldering typeT1 in and T4 out designT1 in and T4 out designPulse excitation, single or double coil

All values above are taken from the GRT product data for each model. Footprint area is calculated from the listed outline dimensions and is provided for panel planning only.

Three readings of the table matter more than the rest:

  • Pole count does not buy current. GRT508BG (1-pole) and GRT508BJ (2-pole) both sit at 90 A resistive, 250 VAC. Moving to two poles gives a second contact set at the same rating, not a higher one.
  • The 2-pole penalty is not uniform. GRT508BJ consumes 2,336 mm², about 2.05 times the 1-pole footprint. GRT508BW achieves two 80 A poles in 1,668 mm² — roughly 1.46 times the 1-pole area, and less per pole than the 1-pole model. If panel space is the binding constraint, GRT508BW is the 2-pole unit to evaluate first, provided 80 A and a 10,000 OPS electrical endurance suit the load profile.
  • Endurance data is asymmetric. Only GRT508BW states an electrical endurance figure in the supplied data. For GRT508BG, GRT508BJ and GRT508BV, electrical endurance is absent, which is a documentation gap rather than a performance claim — request the figure before finalising a life-cycle calculation.

Certification evidence: separating a stated claim from a certificate

ModelCompliance stated in product dataThird-party certificate recordCertificate identifierStandards listed
GRT508BGIEC 62055-31 UC2 compliant; RoHS compliantNone recorded for this model——
GRT508BJIEC 62055-31 UC2 compliant; RoHS compliantNone recorded for this model——
GRT508BVIEC 62055-31 UC2 compliant; RoHS compliantUC2 safety certification, TUV Rheinland, EU marketAK 50686063 0001EN 62052-31:2016; IEC 62052-31:2015
GRT508BWIEC 62052-31 UC2 compliant; RoHS compliantCE, INTEGRA96, EU market, valid 2023-07-13 to 2028-07-13TTC-23-1307/02/02EN 61810-1:2015+A1:2020; IEC 61000-6-1:2019

Certificate records as supplied for this comparison. Absence of a record in this table means no certificate was supplied with the model data — it does not by itself prove non-certification.

The distinction between the two right-hand columns is the practical takeaway. A compliance statement in product data describes an intended classification; a certificate identifier issued by a named body is evidence a qualification engineer can file. If the destination market requires UC2 evidence for a payment meter, GRT508BV is the model in this group with a document to attach. If the requirement is CE under EN 61810-1, GRT508BW carries it.

Certification density varies across the wider GRT latching relay range, which is relevant when a project spans several current classes: GRT508H holds UC3 certification from DEKRA (3151569.01AOC and 3145612.01AOC) to IEC/EN 62055-31:2005 Annex C; GRT508FH holds UC3 certification from TUV Rheinland (AK 50418526 0001); GRT508FA holds UC2 from TUV Rheinland (AK 50234055 0001); GRT508B has TUV Rheinland certificate R 50554074 covering the GRT508B-60A-1B-xVDC-y type at 60 A resistive, 250 VAC; GRT508E holds UL recognition (UL-US-L340054-21-20210202-1, UL508 18th Ed.); and the GRT508Y series holds VDE certificate 40039308. The practical lesson: certification follows the model and type designation, not the brand. Always quote the full type code.

Step-by-step: how to settle the 1-pole vs 2-pole question

Step 1 — Define what must open, not what must carry

Write down the number of circuit paths that must be opened on command. One path points to a 1-pole device such as GRT508BG. Two paths point to GRT508BJ, GRT508BV or GRT508BW. This decision is separate from the current rating and should be recorded first, because it fixes the terminal count and the housing family.

Step 2 — Fix the current and voltage envelope

All four models share a 250 VAC maximum switching voltage. The current envelope splits the group: 90 A resistive for GRT508BG and GRT508BJ, 80 A listed for GRT508BV and GRT508BW. All four state the same short-circuit withstand of 2500 A/10 ms and 4500 A/10 ms without explosion, so the differentiator is continuous rating and endurance, not fault behaviour.

Step 3 — Check the footprint and terminal style against the enclosure

GRT508BG is PCB soldering at 38 × 30 × 16.5 mm, which suits a board-mounted meter where the relay sits on the PCB and the current path is soldered. GRT508BJ, GRT508BV and GRT508BW use fast-connection terminals at 64 × 36.5 × 18.3 mm, 52.5 × 35 × 17.7 mm and 55.6 × 30 × 16.5 mm respectively. The 17.7 mm and 16.5 mm heights of GRT508BV and GRT508BW sit closer to the 16.5 mm of the 1-pole part than the 18.3 mm of GRT508BJ. Confirm terminal clearance and creepage distance against the meter's internal layout before locking the choice.

Step 4 — Match the coil drive to the control board

All four accept 5–24 VDC coils, so the same control rail can drive any of them. Two details still need confirmation per model: whether the coil is single or double, and whether pulse excitation is specified. GRT508BW lists pulse excitation for both single-coil and double-coil versions; for GRT508BG, GRT508BJ and GRT508BV, confirm the coil variant on the datasheet. GRT offers single-coil and double-coil customisation, along with voltage and laser marking customisation, on an OEM/ODM basis.

Step 5 — Attach the evidence the destination market accepts

Assemble the document set per market: 62055-31 UC2 or UC3 certification for payment metering, EN 61810-1 for general relay safety, and a RoHS declaration under Directive 2011/65/EU for EU placement. Map each required document to a specific model and certificate number, as in the table above. Where a model states compliance but no certificate is on file, request the certificate before design freeze rather than after the pilot build.

Use cases that map to each configuration

  • Single-path switching on a board-mounted meter. GRT508BG: 1-pole, 90 A, PCB soldering, 38 × 30 × 16.5 mm. Best fit when the relay is soldered directly and only one circuit path must open.
  • Two-path switching at the highest rating in the group. GRT508BJ: 2-pole, 90 A, fast connection, T1 in and T4 out design. Chosen when both 90 A and two poles are non-negotiable and the 64 × 36.5 × 18.3 mm envelope is available.
  • Two-path switching where a UC2 certificate must be filed. GRT508BV: 2-pole, UC2 certificate AK 50686063 0001, 52.5 × 35 × 17.7 mm. Confirm the 60 A or 80 A current variant in writing before the RFQ.
  • Space-constrained 2-pole designs with a stated endurance target. GRT508BW: 2-pole, 80 A, 55.6 × 30 × 16.5 mm, 10,000 OPS electrical endurance, CE certificate. The smallest 2-pole footprint in the comparison.

A fifth scenario cuts across all four: prepaid and smart meter designs that need remote connect and disconnect with no standing coil current. That requirement is satisfied by the latching principle itself rather than by pole count, so it should be treated as a baseline filter before the pole decision is even taken.

Frequently asked questions

Which of these four models has third-party certification evidence for metering use?

GRT508BV holds UC2 safety certification AK 50686063 0001 issued by TUV Rheinland for the EU market, listing EN 62052-31:2016 and IEC 62052-31:2015. GRT508BW holds CE certificate TTC-23-1307/02/02 issued by INTEGRA96 against EN 61810-1:2015+A1:2020 and IEC 61000-6-1:2019, valid from 2023-07-13 to 2028-07-13 for the EU market. GRT508BG and GRT508BJ are described as IEC 62055-31 UC2 compliant and RoHS compliant in their product data, but no certificate record was supplied with those model documents, so the certificates should be requested directly before qualification. A stated compliance level is a specification claim; the certificate identifier and issuing body are the evidence.

Does a 2-pole latching relay switch twice the current of a 1-pole model?

No. Pole count changes how many separate circuits switch from one coil pulse, not the rating of each contact. In this group, GRT508BG (1-pole) and GRT508BJ (2-pole) are both rated 90 A resistive at a 250 VAC maximum switching voltage, while GRT508BV and GRT508BW (both 2-pole) are listed at 80 A. A 2-pole unit therefore provides two contacts at the stated rating rather than double the current capacity on one path. Buyers who need to open two circuit paths choose a 2-pole model; buyers switching a single path can use the 1-pole GRT508BG and save close to half the board area.

What drives the cost difference between the 1-pole and 2-pole versions?

The main cost drivers are the second contact set and its precious-metal contact material, the larger housing and terminal hardware, the terminal style (PCB soldering versus fast connection), and the certification scope required for the destination market. Customisation also moves the number: GRT supports single-coil or double-coil builds, external accessories such as current transformers, shunts, wire harnesses and brush wires, voltage options and laser marking, all on an OEM/ODM basis. Minimum order quantity for the range is 100 units and production lead time is 30–45 days. This article does not quote prices because no verified price data is available for these models; a quotation should be requested against a fixed specification that names the model, the current variant and the certification requirement.

Can I test both pole configurations before committing to a design?

Yes. Three to five free samples of standard models are available for testing, with the buyer covering the freight cost; custom products require further confirmation. For this comparison, the useful pairing is GRT508BG plus the one 2-pole model whose footprint your enclosure can actually accept — GRT508BJ at 64 × 36.5 × 18.3 mm, GRT508BV at 52.5 × 35 × 17.7 mm or GRT508BW at 55.6 × 30 × 16.5 mm. Testing both lets you validate the footprint and terminal fit on the real assembly rather than on a drawing.

What are the MOQ and lead time for these metering latching relays?

The stated minimum order quantity is 100 units, with a production lead time of 30–45 days, and every unit is tested before shipment. Both figures apply to the latching relay range as a whole rather than to one model, so they should be reconfirmed against the specific configuration — particularly where custom coil, wiring or shunt assemblies are involved. To move from comparison to quotation, send the model, pole count, current rating and target certification to the GRT Relay team and request a sample set and a quotation in the same enquiry.

Conclusion: decide on constraints, not on pole count

There is no universal winner between one pole and two. The verified data supports a simple decision sequence:

  • One circuit path, PCB-mounted, 90 A: GRT508BG — 38 × 30 × 16.5 mm, PCB soldering, 90 A resistive, 250 VAC.
  • Two circuit paths at 90 A with fast-connection terminals: GRT508BJ — 64 × 36.5 × 18.3 mm, T1 in and T4 out design.
  • Two circuit paths where a UC2 certificate must be filed: GRT508BV — 52.5 × 35 × 17.7 mm, certificate AK 50686063 0001, with the 60 A or 80 A variant confirmed in writing.
  • Two circuit paths in the tightest space with a stated endurance figure and CE: GRT508BW — 55.6 × 30 × 16.5 mm, 10,000 OPS electrical endurance, CE certificate TTC-23-1307/02/02.

Two checks should accompany any of these choices. First, confirm electrical endurance for GRT508BG, GRT508BJ and GRT508BV, since only GRT508BW states it in the supplied data. Second, treat compliance statements and certificates as different documents, and request the certificate that matches the full type code you are ordering — the GRT range shows clearly that certification is issued per model and per type designation.

GRT Relay manufacturing workshop for latching relay production in Jiashan, Zhejiang
GRT Relay manufactures latching relays, current transformers and manganese copper shunts at its Jiashan, Zhejiang facility.

GRT Relay is the brand of Zhejiang Great Electrical Co., Ltd., a manufacturer established in 2003 in Yueqing, Wenzhou and now based in Yaozhuang Town, Jiashan County, Jiaxing City, Zhejiang Province, China. The company operates a 50,000 m² facility with approximately 500 employees and a 60-engineer R&D team, produces latching relays, current transformers and shunts for smart meters, smart homes, EV charging, photovoltaic and energy storage equipment, and exports to markets including the EU and India. It is a national high-tech enterprise, a national-level specialised and new little giant enterprise, listed on the New Third Board in 2016 and in the innovation layer since 2017 under stock code 838484.

Move from comparison to a tested sample

Tell us your pole requirement, current rating and target certification, and we will confirm the matching model, coil variant and certificate documents, then arrange a sample set for validation on your meter assembly.

Contact: Annie  |  Mobile / WhatsApp: +86 13626734569  |  WhatsApp: +86 18057329886

Email: sales5@great-relay.com  |  Website:en.grtrelay.com

Address: No.9 Linhu Avenue, Yaozhuang Town, Jiashan County, Jiaxing City, Zhejiang Province, China

Download the full product range: Catalogs of Great-relay (2025) — PDF

Structured data

Have Questions or Need More Details?

Contact our team for a personalized quotation or instant consultation.

Request a Quotation

Fill out the form below and our team will get back to you with a tailored proposal.

Attach images, files, or documents.

We'll respond within 24 hours (Mon–Sat).

WhatsApp Direct Chat

Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.

  • Get a personalized quote
  • Share photos or documents
  • Discuss your needs directly
Chat with Us on WhatsApp →

Typically replies in 5–30 minutes during business hours.

Support: Images, videos, PDF