LoRaWAN Node Module Comparison: WB25 vs. WB26 vs. LP26 for Consumer IoT

Choosing among the Lierda WB25, WB26 and LP26 LoRaWAN node modules comes down to which constraint binds first in your product: enclosure space, input-voltage window, or link margin. WB25 and WB26 are 22×18×3.0 mm modules with a 1.8V–3.6V operating range, LoRaWAN Class A and Class C support, 22 dBm transmit power and -137 dBm sensitivity. LP26 is a 25×21×3.0 mm module with a 3.6V–5.2V input range, up to 29 dBm transmit power and higher current demand than either of the smaller modules.
Lierda Science & Technology Group Co., Ltd. is an IoT module and solution provider founded in 2001 and headquartered in Hangzhou, China, whose wireless portfolio includes LoRa, NB-IoT, Cat.1, Wi-Fi, Wi-Sense and other module families. Within that portfolio these three parts sit close together on protocol but far apart on mechanical and electrical fit, which is why they are not interchangeable at the layout stage. A team that starts from the radio number and works backwards usually ends up re-spinning the board, re-testing the antenna and rebuilding the battery estimate.
This guide sets out the order that works: mechanics first, power source second, link budget third. It compares the three modules only on facts that are documented, and it marks clearly where the published record stops.
The decision problem: three constraints, one part number
A LoRaWAN node module fixes four things at once: the board area it occupies, the power architecture built around it, the achievable link budget, and the compliance route into each market. The choice is therefore a constraint-elimination exercise rather than a specification comparison.
The constraints pull against each other. Transmit power comes from a power amplifier, and a higher output needs more supply headroom and more current during the transmit burst. Packaging follows: the module rated at up to 29 dBm is 25×21 mm with a 3.6V–5.2V input, while the 22 dBm modules fit into 22×18 mm and accept 1.8V–3.6V. The extra link margin cannot be separated from the larger footprint and the higher rail.
In practice, three questions decide the part number, in this order:
- Does the enclosure accept 25×21×3.0 mm, including the antenna keep-out and the decoupling that the higher current demand implies?
- Does the product's power source sit inside 1.8V–3.6V, or can it provide 3.6V–5.2V?
- Does the link budget close at 22 dBm with -137 dBm sensitivity, or does it need the additional output that LP26 offers?
If the first two answers point to the larger module, LP26 is the candidate. If either rules it out, WB25 or WB26 becomes the default, and the remaining choice between them rests on the protocol behaviour you need rather than on mechanical or electrical limits.
Industry background: why the specification is set at module level
LoRaWAN is a low-power wide-area network protocol built for sub-GHz operation, low data rates and duty-cycled traffic. A node sleeps for most of its life, wakes to send a short payload, and listens in a narrow window afterwards. That pattern is what makes long operation from a small cell realistic, and it is also why module-level current consumption and receiver sensitivity matter more than peak throughput.
The band plan is regional. Lierda's published material for the WB25-8D lists an operating band of 860–930 MHz with LoRaWAN regional plans for EU868, IN865, RU864, AU915, US915, KR920 and AS923-1/-2/-3/-4, over a UART interface. The STMicroelectronics partner page for Lierda describes the same device as a LoRaWAN end-node module conforming to the LoRaWAN protocol stack and regional parameters, and describes the WB26-7P as a LoRa transparent module using a serial interface.
Two consequences follow for a consumer product team. First, a module family usually ships in several band-specific variants, so one mechanical design can serve several markets only if the layout keeps those variants interchangeable. Second, protocol conformance and market approval are separate things: a module that implements the LoRaWAN stack still needs country-level type approval before the finished product can be sold there. If the product is sold in Europe, the Radio Equipment Directive's cybersecurity requirements took effect on 1 August 2025, which changes the design evidence and documentation the product will be asked to produce.
Class selection belongs here too. Class A is the uplink-driven default: the radio opens two short receive windows after each transmission. Class C holds the receiver open continuously, giving low-latency downlink at the cost of continuous current. WB25 and WB26 support both classes, so the class you configure is a power-budget decision rather than a module-selection decision.

What each module is, and what the record covers
WB25 — the compact end-node module
WB25 is specified at 22×18×3.0 mm, operating from 1.8V to 3.6V, with LoRaWAN Class A and Class C support, 22 dBm transmit power and -137 dBm sensitivity. The catalogue designation WB25-8D adds a UART interface and LoRaWAN regional plans across 860–930 MHz. For a consumer team the practical reading is: a single-cell supply is sufficient, the module occupies just under 400 mm² of board area, and the RF budget is set by a 22 dBm transmitter paired with a -137 dBm receiver.
WB26 — the same envelope, different protocol behaviour
WB26 shares the 22×18×3.0 mm form factor, the 1.8V–3.6V range, Class A and Class C support, 22 dBm transmit power and -137 dBm sensitivity. The variant identified in the STMicroelectronics listing, WB26-7P, is described as a LoRa transparent module with a serial interface rather than as a LoRaWAN end node. That distinction matters at integration time: a transparent module passes raw LoRa payloads over the serial link and leaves more network behaviour to the host firmware, while an end-node module carries the LoRaWAN stack itself. Confirm which behaviour applies to the specific ordering part number before the layout is frozen.
LP26 — the larger module with the higher output
LP26 is specified at 25×21×3.0 mm with a 3.6V–5.2V input range and up to 29 dBm transmit power, and it draws more current than the two smaller modules. Those published facts are the whole basis for choosing it: it serves designs that have a higher supply rail available, can afford the board area, and need the extra output.
A note on scope. This comparison uses the module facts confirmed for these parts: dimensions, input voltage, transmit power, sensitivity, class support, and the documented interface and band information. Other parameters a design team will eventually need — pin-out, current in milliamps, operating temperature range, memory, and country certificates — are not stated in those sources and are therefore not quoted here. Their absence from this page is not evidence that a module lacks them; it means the figures must come from the datasheet and certificate for the exact part number.
Step by step: choosing in the order that matters
Step 1 — Lock the mechanical envelope
Measure the space you actually have, not the space you hope for. All three modules are 3.0 mm thick, so height is not the differentiator; area is. WB25 and WB26 occupy 396 mm² and LP26 occupies 525 mm², about 33% more board area (calculated from the published dimensions). Add the antenna keep-out and the ground-plane clearance your antenna needs, then decide whether 25×21 mm survives. In a wrist-worn device or an in-wall sensor, this step usually ends the comparison immediately.
Step 2 — Map the power source
A 1.8V–3.6V window suits a single lithium primary cell or a pair of alkaline cells across their useful discharge range, and it lets the radio run directly from the rail without a boost stage. A 3.6V–5.2V window implies a different architecture: a 5V USB supply, a multi-cell pack, or a boost converter in front of the module. Each option adds components, quiescent current and board area, and a boost converter's efficiency has to be counted against the link-margin gain it enables.
Then consider current. LP26's higher current demand affects three things: the peak-current capability of the chosen cell or supply, the bulk capacitance needed to hold the rail stable during a transmit burst, and the average consumption that sets battery life. Because the sources used here do not publish milliamp figures for these modules, the reliable sequence is to obtain the datasheet current profiles and measure them in your own duty cycle.
Step 3 — Build the link budget before comparing radios
Link budget is transmit power plus antenna gain minus path loss plus receiver sensitivity, and the module supplies only two of those terms. One part of the comparison is arithmetic: LP26's up-to-29 dBm output against the 22 dBm rating of WB25 and WB26 gives roughly 7 dB of additional transmit power, about five times the radiated power (calculated from the two published ratings). Both WB25 and WB26 are specified at -137 dBm sensitivity, while LP26's receive sensitivity is not stated in the sources used here, so the receive side of the comparison cannot be closed from published material alone.
Seven decibels is a meaningful quantity in a link budget, but it does not convert into a fixed distance multiplier. The improvement depends on the propagation environment — open field, in-building, dense urban — and on the antennas at both ends. What the figure does tell you is directional: a design short of margin by a few decibels is exactly the case for LP26, and a design with comfortable margin gains nothing measurable by paying for it.
Regional regulation sits on top of this. Permitted transmit power and duty cycle are set by the band plan of the country of deployment, so the usable advantage of a higher-power module depends on what local rules allow and on the antenna gain of the finished product. Confirm the limit for the specific band before designing around 29 dBm.
Step 4 — Choose the class from the power source
If the product runs from a battery, Class A is the sensible configuration: the receiver is closed between uplinks, and energy consumption tracks the reporting interval. If the product is mains-powered and must accept downlink commands quickly, Class C is available on WB25 and WB26 and should be evaluated against its continuous receive current. A Class C node on a primary cell is a contradiction regardless of which module carries it.
Step 5 — Confirm band variants and approval route
Decide the countries of sale before the layout, because band variants determine the matching network and sometimes the module order code. For the WB25-8D, the published plan list covers the common European, Indian, Russian, Australian, US, Korean and Asian regional plans. Request the certificate and test report for the exact model and market, and keep protocol conformance and type approval as two separate lines in the compliance file.
Step 6 — Protect the antenna and the ground plane
A 22×18 mm module leaves more room for a keep-out zone and for matching components, which is an underrated benefit in small consumer enclosures. A 25×21 mm module needs 129 mm² more board area and the same antenna clearance, so the surrounding layout has to be planned together with the module choice. If the enclosure is metal, or the antenna sits close to a battery or a display, the practical link margin may be decided by the mechanics rather than by the module's transmit power.
Step 7 — Validate with samples in your own enclosure
Bench specifications do not survive a plastic case, a battery and a hand. Request samples of the exact part numbers, assemble them on your production-intent layout, measure current across your real reporting interval, verify join behaviour and Class A/Class C operation, and run a walk test at the edge of the intended coverage. This is also the point to confirm the WB26 variant's protocol behaviour: whether it acts as a LoRaWAN end node or as a transparent serial LoRa module changes both the firmware effort and the test plan.
Use cases: which module fits which consumer product
The following are conditional design scenarios rather than documented customer projects. They show how the constraints combine in practice.
Battery sensor in a small housing
A door or window contact, a water-leak sensor or a temperature and humidity puck has a coin or AA cell, a housing measured in centimetres, and a reporting interval of minutes to hours. The 1.8V–3.6V window and the 22×18×3.0 mm footprint of WB25 or WB26 match that envelope directly, and Class A keeps the receive path closed between reports. The LP26 footprint and 3.6V–5.2V input would force both a mechanical change and a boost stage for a capability the product cannot use.
Mains-powered controller with downlink requirements
A consumer hub, valve controller or relay module that is permanently powered and must react to commands promptly can justify Class C. With a 5V rail already available, LP26's 3.6V–5.2V input fits without conversion, and its higher current demand is a secondary concern in a mains-powered product. WB25 or WB26 remain viable if the 5V rail is regulated down and the extra link margin is not required.
Long-range outdoor or rural installation
A garden irrigation controller, a gate opener or a rural sensor node often sits far from the nearest gateway and inside a thicker enclosure. That is the case where 22 dBm may fail to close the budget and LP26's up-to-29 dBm output earns its board area. The decision should still come from a measured link budget — gateway position, antenna gain, enclosure loss — rather than from the assumption that more power is always better.
Retrofit into an existing 3V design
When a product already runs from a 3V rail and the enclosure is tooled, the electrical and mechanical constraints are fixed. WB25 or WB26 can drop into the existing rail and, at 22×18 mm, into the existing board area, while LP26 would require a rail change and a mechanical change at the same time. In a retrofit, the module with the fewest dependencies is the practical choice even when the RF specification is less generous.

Side-by-side comparison: WB25, WB26 and LP26
The table below collects only the published values for the three modules. Where a figure is not published in the sources used for this comparison, the cell says so rather than estimating.
| Parameter | WB25 (WB25-8D) | WB26 (WB26-7P) | LP26 |
|---|---|---|---|
| Footprint | 22×18×3.0 mm | 22×18×3.0 mm | 25×21×3.0 mm |
| Input voltage | 1.8V–3.6V | 1.8V–3.6V | 3.6V–5.2V |
| Transmit power | 22 dBm | 22 dBm | up to 29 dBm |
| Receiver sensitivity | -137 dBm | -137 dBm | not stated in the sources used here |
| LoRaWAN class | Class A / Class C | Class A / Class C | not stated in the sources used here |
| Interface | UART (WB25-8D) | serial interface (WB26-7P) | not stated in the sources used here |
| Frequency plans | 860–930 MHz; EU868, IN865, RU864, AU915, US915, KR920, AS923-1/-2/-3/-4 (WB25-8D) | not stated in the sources used here | not stated in the sources used here |
| Current demand | lower than LP26 in this comparison | lower than LP26 in this comparison | higher than WB25 and WB26 |
| Typical fit | tight enclosure, single-cell supply | tight enclosure, serial LoRa integration | larger enclosure, 3.6V–5.2V rail, extra link margin |
Not stated means the sources used for this comparison do not publish the figure; it does not mean the module lacks that capability. Confirm every value against the current datasheet and certificate for the exact ordering part number before design freeze.
Where the published data stops
Three questions will decide the final part number in most consumer projects, and none of them is answered by the figures above. The first is current consumption in milliamps at a stated duty cycle, which determines battery life and bulk capacitance; without it, a battery estimate is an assumption. The second is the operating temperature range, which decides whether the module suits outdoor or appliance-mounted products. The third is country certification, which decides whether the product can ship to each target market at all. Each of these belongs in an RFI to the supplier and in the design verification plan, and each should be answered in writing for the exact model.
Frequently asked questions
Which regional LoRaWAN bands do these modules support, and is band support the same as certification?
WB25-8D is documented with LoRaWAN regional plans EU868, IN865, RU864, AU915, US915, KR920 and AS923-1/-2/-3/-4 over an operating band of 860–930 MHz with a UART interface, and the STMicroelectronics partner page describes it as conforming to the LoRaWAN protocol stack and regional parameters. Band support and protocol conformance are not the same as country-level type approval: confirm the certificate and test report for each model and each market. For LP26, the frequency plans and certification status are not stated in the sources used here and must be confirmed with the supplier. For European sales, note that the Radio Equipment Directive's cybersecurity requirements took effect on 1 August 2025 and add the corresponding design evidence to the file.
Can WB25 or WB26 replace LP26 where 29 dBm is specified?
Not on transmit power alone. WB25 and WB26 are rated at 22 dBm, while LP26 is rated at up to 29 dBm — roughly 7 dB, or about five times the radiated power, calculated from the two published ratings. Whether that difference matters depends on the whole link budget: antenna gain at both ends, enclosure loss, gateway sensitivity and the propagation environment. If the budget analysis shows the design is short by a few decibels, a 22 dBm module cannot supply them; if the budget already closes with margin, the 22 dBm module is available and smaller. Regional power limits can also cap the usable advantage of the higher-power part, so check the band plan for the country of deployment first.
Which module costs less to build into a product?
Unit pricing and minimum order quantities are quotation-specific and are not published in the sources used here. What can be compared is system cost. WB25 and WB26 occupy 396 mm² of board area against 525 mm² for LP26, about 33% less (calculated from the published dimensions). LP26's 3.6V–5.2V input needs a 5V rail, a multi-cell pack or a boost stage, whereas the 1.8V–3.6V modules can run from a single cell. LP26's higher current demand affects cell selection and bulk capacitance. Add the enclosure size and the cost of qualifying band variants for each market, and compare the complete figure rather than the module price line.
How should a team validate a module before committing to production?
Order evaluation samples of the exact ordering part numbers — WB25, WB26 and LP26 — and put them through the same test plan. Build them on production-intent boards with the antenna you intend to ship, measure current across the real reporting interval, verify network join and Class A and Class C behaviour, and run a walk test at the edge of the planned coverage. Repeat the test inside the final enclosure. For WB26, confirm at the same time whether the ordered variant behaves as a LoRaWAN end node or as a transparent serial LoRa module, because that determines how much of the stack your firmware must carry.
What lead time and supply commitment should a consumer IoT project plan for?
Model-level lead times, minimum order quantities and delivery schedules are not published in the sources used here; they are confirmed at quotation for the specific model, band variant and volume. What can be assessed publicly is the supplier's operating base: Lierda was founded in 2001, reports an 18,000 m² facility, employees in the high hundreds and a research team of more than 200 engineers, and states that it offers OEM, ODM and EMS services alongside its module business — capabilities worth verifying through an audit and a sample order before they are written into a production plan. The practical next step is to request samples and a quotation for WB25, WB26 and LP26 against the same specification so that lead time, documentation and technical support can be compared on equal terms.
Conclusion: decide in the order mechanics, power, then radio
For consumer IoT products, the WB25/WB26 versus LP26 decision is a sequencing decision. Start with the enclosure: if 25×21×3.0 mm does not fit, LP26 is out and the choice narrows to WB25 and WB26, which share the 22×18×3.0 mm footprint, the 1.8V–3.6V range, Class A and Class C support, 22 dBm output and -137 dBm sensitivity. Then check the power source: a single cell favours the smaller modules, while an existing 3.6V–5.2V rail makes LP26 practical. Only then should the radio decide, and it should decide from a link budget that includes antenna gain, enclosure loss and regional power limits — not from the transmit power rating alone.
Between WB25 and WB26 the mechanical and electrical data are identical, so the difference documented here is protocol behaviour: WB25-8D is described as a LoRaWAN end node carrying the stack, and WB26-7P is described as a LoRa transparent module driven over a serial interface. Confirm the firmware split you want, and the figures your datasheet adds to this comparison, before the part number is frozen.
Next step. Request evaluation samples of WB25, WB26 and LP26 for the same enclosure and run them through one duty cycle and one field test. Lierda supports module selection with samples, technical documentation and OEM/ODM discussion through en.lierda.com.
Company and product catalogue: download the Lierda brochure (PDF).
Have Questions or Need More Details?
Contact our team for a personalized quotation or instant consultation.
Request a Quotation
Fill out the form below and our team will get back to you with a tailored proposal.
WhatsApp Direct Chat
Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.
- Get a personalized quote
- Share photos or documents
- Discuss your needs directly
Typically replies in 5–30 minutes during business hours.