Model 520302-01068 · Module Interconnect Busbar · C11000 copper foil with EVA heat-shrink insulation

Model 520302-01068 is a module interconnect flexible copper busbar built from multilayer C11000 copper foil and insulated with flame-retardant EVA heat-shrink tubing. The laminated foil structure lets the conductor flex with vibration and thermal expansion instead of transferring that movement to cell terminal welds, and a nickel lamination surface finish is applied to the copper. Conductivity is 97% IACS or higher, supporting low-resistance current paths inside EV battery modules. The insulation system is rated UL 94 V-0 and withstands 4000 V DC for 60 seconds without dielectric breakdown.
The laminated foil conductor absorbs vibration and thermal expansion, helping reduce mechanical stress on cell terminal welds inside battery packs.
High-conductivity copper keeps resistance low. In 400 V-class EV battery systems the busbar is specified for 100-200 A continuous and 200-400 A short-term peak, subject to validation.
Nickel lamination is applied to the C11000 copper foil as the documented surface finish of the conductor.
1.0-1.5 mm EVA heat-shrink tubing insulates the foil; the material is rated UL 94 V-0 under a CNAS-accredited test report.
Rated 4000 V DC for 60 seconds with no breakdown and leakage current below 0.5 mA; insulation resistance is at least 500 MOhm at 1000 V DC.
The flexible conductor routes through space-constrained battery packs, and both ends are welded and punched with mounting holes for on-site installation.


| Parameter | Specification |
|---|---|
| Model | 520302-01068 |
| Product Type | Module Interconnect Busbar |
| Conductive Material | C11000 copper foil, multilayer |
| Surface Finish | Nickel Lamination |
| Insulation Material | EVA heat-shrink tubing |
| Insulation Thickness | 1.0-1.5 mm |
| Temperature Resistance | -50 to +125 C |
| Flammability Rating | UL 94 V-0 |
| Conductivity | 97% IACS or higher |
| Insulation Resistance | 500 MOhm or higher at 1000 V DC for 60 s |
| Dielectric Withstand Voltage | 4000 V DC for 60 s, no breakdown, leakage current below 0.5 mA |
| Termination | Both ends welded and punched with mounting holes |
Flame retardancy verified in CNAS-accredited report A2260454824101002E (UL 94-2023, CTI, issued 2026-06-23). Nickel-plated copper foil tested to RoHS Directive 2011/65/EU with amendment (EU) 2015/863 under report A2260444277101004E.
The conductor is a stack of C11000 copper foils bonded into a flexible laminate, finished with nickel lamination on the copper. EVA heat-shrink tubing of 1.0-1.5 mm covers the conductor body for dielectric protection and moisture resistance. Both ends are welded and punched with mounting holes so the part can be bolted directly during pack assembly. RHI produces flexible busbars in an automated welding workshop operating more than 60 polymer welding machines and in a dedicated heat-shrink workshop with automatic heat-shrinking equipment.

RHI supports customer-specific busbar programs from drawing review and DFM analysis through tooling development, prototype validation, APQP and PPAP documentation, and mass production. The in-house tooling center develops more than 100 molds and 200 sets of tooling and inspection fixtures, and production covers stamping, welding, extrusion, PVC dipping, injection molding and 3D bending for complex conductor shapes.
A battery manufacturer has sourced flexible copper busbars from RHI for new energy vehicle power battery module interconnection over an 8-year supply relationship.
Reported results: reduced power loss, reliable operation and cost optimization.
What current rating applies to this busbar?
In 400 V-class EV battery systems the documented range is 100-200 A continuous and 200-400 A short-term peak, subject to validation in the final application.
What dielectric values are specified?
4000 V DC for 60 seconds with no dielectric breakdown and leakage current below 0.5 mA, plus insulation resistance of at least 500 MOhm at 1000 V DC for 60 seconds.
What is the operating temperature range?
-50 C to +125 C.
Is the flame retardancy certified?
Yes. The EVA heat-shrink tubing is rated UL 94 V-0 in CNAS report A2260454824101002E, tested to UL 94-2023 by CTI and issued 2026-06-23.
Is the busbar RoHS compliant?
Nickel-plated copper foil is tested to RoHS Directive 2011/65/EU with amendment (EU) 2015/863 under report A2260444277101004E.
Which insulation thickness can be supplied?
EVA heat-shrink tubing in the 1.0-1.5 mm range.
Can the hole pattern and length be customized?
Yes. Terminal geometry, hole pattern and conductor length are produced to the customer drawing after drawing review, DFM analysis and prototype validation.
How is the busbar mounted in the pack?
Both ends are welded and punched with mounting holes so the part can be installed on site during module assembly.
Supplier: Zhejiang RHI Electric Co., Ltd. (founded 2011, IATF 16949, ISO 14001, ISO 45001)
Contact: Mr. Wu | Tel: +86 577 6198 8777 | WhatsApp: +86 158-6802-5551
Email: sales@rhielec.com | Website: www.rhibusbar.com
Factory 2: No. 161 Jingqi Road, Yueqing Economic Development Zone, Yueqing City, Wenzhou, Zhejiang, China
Send your drawing, current rating and pack layout for drawing review and DFM feedback on model 520302-01068.