{{ variable.name }}
Modular-configuration nitrogen generator for electronics and semiconductor production: 80–800 Nm³/h, 0.7 MPa adsorption pressure, PLC data monitoring with more than 30 days of retained records.

This modular configuration is built for plants where nitrogen is a process utility rather than a bulk commodity — electronics assembly, reflow and wave soldering, and cleanroom-adjacent semiconductor work. Nitrogen is generated on site from compressed air at 0.7 MPa adsorption pressure, across a flow range of 80–800 Nm³/h and an air demand of 2.4–24 Nm³/min. VP control keeps the air-to-nitrogen ratio stable when line load changes, while the unequal-pressure equalisation structure raises adsorbent utilisation by 20%. The PLC controller stores operating data for more than 30 days, which gives process engineers a traceable record of purity-relevant run conditions for shift reviews and internal audits.
The PLC integrates data monitoring and storage, so operating history stays available for troubleshooting and production audits.
An energy-efficient unequal-pressure equalisation structure lifts adsorbent utilisation by 20% compared with the conventional equalisation approach.
Vacuum loading, dense-phase packing and a variable-frequency vibration platform prevent settling and pulverisation over an operational life of up to 8 years.
The same packing method raises packing density by 10% inside an adsorption tower of identical volume.
Operating frequency follows demand and the air-to-nitrogen ratio stays stable across the flow range, which suits plants running several shifts at different loads.
In electronics production, the nitrogen is used to prevent oxidation during reflow soldering and wave soldering and in oxygen-free processing environments.
| Parameter | Value |
|---|---|
| Configuration | Modular PSA nitrogen generator |
| Nitrogen flow rate | 80–800 Nm³/h (model dependent) |
| Demand capacity of air | 2.4–24 Nm³/min |
| Adsorption pressure | 0.7 MPa |
| Air inlet | Rp1-1/2, DN50, DN65 |
| Nitrogen outlet | Rp1, Rp1-1/2, Rp2 |
| Weight | 1,100–4,400 kg |
| Control | PLC with data monitoring and storage; Variable-Period (VP) control |
| Materials | Aluminum alloy, stainless steel, carbon steel |
| Model range | SLT-80N, SLT-130N, SLT-170N, SLT-200N, SLT-250N, SLT-320N, SLT-400N, SLT-480N, SLT-600N, SLT-700N, SLT-800N |
| Management system | ISO 14001, certificate 05126E00664R053 issued by NOA, valid to 2029-03-26 |
The modular type shares the SLT-80N to SLT-800N model range with the twin tower and combined configurations, covering 80–800 Nm³/h, 2.4–24 Nm³/min air demand and 1,100–4,400 kg. Selection between the three configurations depends on plant layout, gas-demand profile and how the generator ties into existing air treatment. Flow rate, connection size and weight for a named model are confirmed at quotation against the duty point.
Vessels, piping and frame can be supplied in aluminum alloy, stainless steel or carbon steel to suit the room the unit sits in — stainless steel where washdown or humidity is present, carbon steel for ordinary indoor plant space. Molecular sieve is vacuum loaded and dense-phase packed so the bed does not settle; an unequal-pressure equalisation structure links the vessels and recovers pressure between them instead of venting it to atmosphere.
High-cleanliness, precision conditions with oil-free air, stable pressure and control of humidity and contamination. Nitrogen prevents oxidation in reflow and wave soldering and supports oxygen-free processing.
Cleanroom and ultrapure process gas supply with low vibration and low noise requirements. In our application data, the generator is combined with adsorption dryers and A/H-grade precision filters to reach an ultra-low dew point of -70 °C.
OEM and ODM builds are supported, including material selection, connection sizing across Rp1-1/2, DN50, DN65 and Rp1, Rp1-1/2, Rp2, and control integration with the plant PLC network. Sollant runs a 30,000 ㎡ facility with 20 R&D engineers and 20,000 units annual output; purity, dew point and pressure targets are fixed per project during quotation.
Yes. Our electronics and semiconductor application data specifies Class 0 oil-free air supply with A/H-grade precision filtration ahead of the generator.
The application data specifies an ultra-low dew point of -70 °C where adsorption dryers and precision filters are combined with the generator. Purity for a specific line is confirmed at quotation.
The PLC retains operational records for more than 30 days.
80–800 Nm³/h with air demand of 2.4–24 Nm³/min; the model is sized on your required flow and purity.
Air inlet Rp1-1/2, DN50 or DN65; nitrogen outlet Rp1, Rp1-1/2 or Rp2, depending on model.
Yes. Matched equipment in our electronics application data includes air compressor, adsorption dryer, precision filter and nitrogen generator, so the upstream package can be quoted together.
Filenames use the product-model-application-view pattern so the electronics variant is not confused with the twin tower or combined variants.