How is performance maintained in thin plateau air?
An altitude oxygen compensation intake port is specified for the plateau configuration, and the programme referenced operation at altitudes up to 5,000 m with stable pressure and delivery.
{{ variable.name }}
GCU33 integrated screw airend for plateau locomotive and coach oxygen / nitrogen systems — oil carry-over ≤3 ppm, −40 °C to +50 °C design, operation up to 5,000 m.
SEO TitleGCU33 Altitude-Compensated Screw Airend for Plateau On-Board Oxygen Generation
Meta DescriptionGCU33 screw airend for plateau oxygen generation: altitude compensation port, −40 °C to +50 °C, oil carry-over ≤3 ppm, 5–12.5 bar, up to 5,000 m operation.
URL Slug/products/gcu33-screw-airend-plateau-oxygen-generation
H1Altitude-Compensated Screw Airend for On-Board Oxygen Generation
Plateau rail service demands compressed air that is clean, dry and consistent, because it feeds the oxygen and nitrogen generators serving passengers and crew. The GCU33 is configured for that duty with an altitude oxygen compensation intake port, a design range of −40 °C to +50 °C and oil carry-over held at or below 3 ppm, delivering 2.3–3.9 m³/min at 7 bar within a 5–12.5 bar range.
The 9-in-1 assembly combines the screw airend, an oil-gas separator tank with built-in coarse separator, three filters and four valves, so the coach or locomotive builder installs one pressure-ready unit of 74 kg in a 477 × 438 × 633 mm envelope excluding the air filter assembly. Noise is rated at or below 75 dB(A), and the unit is specified for continuous duty during plateau operation, matched with an air dryer and precision filter upstream of the generator.


An altitude oxygen compensation intake port maintains stable pressure and delivery in thin air at altitudes up to 5,000 m.
Coarse separator in the tank plus an oversized external fine separator keep the airstream within the ≤3 ppm design limit required by downstream generators.
The platform is designed for −40 °C to +50 °C, covering the day and night temperature difference of plateau routes.
Nine integrated functions in a single 74 kg unit reduce connection work inside a locomotive or coach air bay.
Specified for continuous operation with automatic pressure regulation, with a maximum discharge temperature of 105 °C.
Forged alloy steel rotors on a German-designed UV patented profile, SKF bearings and triple-sealing shaft technology.
| Model | GCU33 |
|---|---|
| Type | Wide-range integrated screw airend; vehicle / general purpose |
| Power | 15–30 kW |
| Speed | 3100–6000 rpm |
| FAD at 7 bar | 2.3–3.9 m³/min |
| Working pressure | 5–12.5 bar (max. 12.5 bar / min. 5 bar) |
| Max. discharge temperature | 105 °C |
| Oil carry-over | <2 ppm (design ≤3 ppm) |
| Noise | ≤75 dB(A) |
| Net weight | 74 kg |
| Dimensions (L×W×H) | 477 × 438 × 633 mm, excluding air filter assembly |
| Plateau configuration | Altitude oxygen compensation intake port; −40 °C to +50 °C design; dry, oil-free air at ≤3 ppm |
| Integrated configuration | 9-in-1: screw airend + oil-gas separator tank (built-in coarse separator) + 3 filters (external fine oil separator, oil filter, air filter optional) + 4 valves (intake control valve, minimum pressure valve, thermostat valve, safety valve) |
| Materials | High-grade cast iron housing; forged alloy steel rotors; SKF heavy-duty rolling bearings; triple-sealing shaft seal |
| Compliance | CE (TUV Rheinland, CE-WSD-GCU-2023-001, valid to 2028-06-14); ISO 9001:2015; IATF 16949:2016 |
Compression takes place between forged alloy steel rotors machined to a German-designed UV patented profile (patent ZL2012 1 0087353.0) in more than 20 precision steps, carried on SKF heavy-duty rolling bearings and sealed by a triple-sealing shaft arrangement. Separation is two-stage: a built-in coarse separator inside the oil-gas tank followed by an oversized external fine oil separator. The high-grade cast iron housing encloses the airend and the factory-fitted valve group, with the minimum pressure valve, thermostat valve, intake control valve and safety valve regulating the air delivered to the downstream dryer and generator.
Configured for plateau oxygen and nitrogen generation and related rail air supply duties.
Altitude compensation, temperature design range, filtration arrangement and mounting interface are agreed per project, with technical drawings issued for the vehicle air bay. Because the airend output feeds a dryer and generator, the specification is normally fixed together with those downstream components so that pressure, flow and oil carry-over match the oxygen or nitrogen plant requirement.
Two-year programme supplying clean, water-free compressed air for on-board oxygen and nitrogen generation. Reported result: normal operation at altitudes up to 5,000 m with stable pressure and delivery. Highlights: altitude oxygen compensation intake port, −40 °C to +50 °C design, oil carry-over ≤3 ppm.
Approx. 300 units shipped cumulatively over 2 years for aftermarket replacement and vehicle air system retrofit. Reported result: CE-compliant supply with purchase cost 25–30% lower than comparable European airends of equivalent performance. Highlights: drop-in replacement dimensions and a 4–5 week lead time versus 8–10 weeks for imports.
An altitude oxygen compensation intake port is specified for the plateau configuration, and the programme referenced operation at altitudes up to 5,000 m with stable pressure and delivery.
The design limit for oil carry-over is 3 ppm, with measured carry-over below 2 ppm, and the unit is matched with an air dryer and precision filter before the generator.
−40 °C to +50 °C, covering the large day and night temperature difference on plateau routes.
2.3–3.9 m³/min FAD at 7 bar within a 5–12.5 bar working range, at 15–30 kW and 3100–6000 rpm, with maximum discharge temperature of 105 °C.
In the referenced programme the unit matched drop-in replacement dimensions, and a standardised mounting interface with technical drawings is provided for integration.
CE issued by TUV Rheinland (CE-WSD-GCU-2023-001, valid to 14 June 2028) covering integrated screw airends and vehicle-mounted screw air compressors from 2.2 to 45 kW, plus ISO 9001:2015 and IATF 16949:2016.
Wuxi Woyo Superdo Compressor Co., Ltd. (brand WOLXAIR), founded 1996, 20,000 m² facility, 120+ staff, 12,000 units annual output.
Email: service@woyo.cn · Tel: +86 510 8599 6655 · WhatsApp / Mobile: +86 189 1237 9878
Address: No.5 Changkang Road, Mashan, Binhu District, Wuxi, Jiangsu, China · www.woyocomp.com
Please confirm operating altitude, required FAD and pressure, downstream dryer and generator specification, and annual quantity so the plateau configuration can be quoted. MOQ, price and delivery are confirmed per configuration.