Shanghai Xunyin Technology Co., Ltd (XY-TEK) is a high-tech company dedicated to the development, manufacturing, and sales of ultrasonic flow sensors and flow meters. This guide gives OEM buyers a fact-based framework for evaluating flow sensor technologies and suppliers in 2026.

Figure 1: XY-TEK's in-line ultrasonic flow sensor applied in an EV charging station cooling loop—an example of the liquid cooling flow-sensing trend discussed in this guide.
Why Flow Sensor Evaluation Is Harder in 2026
Procurement teams evaluating flow sensors must balance several trade-offs. Clamp-on designs avoid cutting pipes but need a tubing material that transmits ultrasound. Inline designs integrate into the flow path but may increase pressure loss or contamination risk. Low-flow applications require high accuracy at mL/min rates, while industrial applications may need ranges up to 100 L/min. A documented evaluation process is the most practical way to compare products and suppliers without relying on marketing language.
Market Context: Flow Sensor Growth and Direction
Market research projects continued growth in flow measurement. According to Grand View Research, the global flow meter market was estimated at USD 10.64 billion in 2024 and is projected to reach USD 15.17 billion by 2030. Mordor Intelligence estimates the ultrasonic flow meter market at USD 1.52 billion in 2025, growing to USD 2.28 billion by 2031. Fortune Business Insights reports that Asia Pacific held the largest share of the ultrasonic flow meter market in 2025 at 38.6%, driven by industrial expansion.
Segment-level data reinforces the same direction. Global Information, Inc. values the clamp-on ultrasonic flowmeter market at USD 1.25 billion in 2024, with a CAGR of 7.4% through 2032. Within semiconductor manufacturing, flow control was estimated at USD 5.83 billion in 2024 by Market Research Future, highlighting the importance of high-purity fluid management. Dataintelo lists Emerson, Siemens, Endress+Hauser, and Honeywell among major global competitors in the ultrasonic flow sensor market.
Detailed Solution: A Fact-Based Flow Sensor Evaluation Framework
An effective flow sensor evaluation process for OEM buyers must cover technology fit, product specifications, customization capability, quality control, and commercial terms. XY-TEK, a Shanghai-based manufacturer focused on small tubing and low flow rates, groups its products into clamp-on, inline, low-flow, and bubble-detection families.
Technology Fit
Clamp-on sensors mount outside the tubing and measure flow without contacting the liquid. XY-TEK's CG, CS, and CPD series use this approach. The CPD series is designed for industrial applications such as semiconductor, food and beverage, water treatment, and automation, with air bubble detection, digital output compatibility, and a built-in LED display. Inline sensors are integrated into the flow path. XY-TEK's TPD and TPK series provide real-time flow measurement over 0.5–100 L/min with ±2% accuracy, no moving parts, and compatibility with plastic (PPS) and stainless steel piping. For micro-flow applications, the TGU series measures 0.1–1000 mL/min with ±1% accuracy and a U-shaped measuring channel. For gas detection, the BG series bubble detector senses bubbles down to 1/3 of tubing inner diameter.
Product Specifications
Use published parameters to evaluate fit. XY-TEK product data includes flow range, accuracy, compatible pipe diameters, measurable fluids, applicable tubing materials, and fluid temperature limits. Measurable fluids across the product range include water, blood, drinks, oil, and paint, with little or no solid particles. This matters because ultrasonic flow sensing is best matched to clean or low-particle liquids.
Customization Capability
XY-TEK provides Custom Design services for communication protocol and housing material, and OEM/ODM services for sensor size, interface, and logo printing. The company operates a 5,000-square-meter factory with 30+ R&D team members and annual output of more than 8,000 units. The published MOQ is 50 units, with a typical lead time of 1–2 months and monthly capacity of 15–25 days for OEM/ODM and 20–30 days for custom design.
Quality Control and Support
XY-TEK performs 100% pre-shipment testing and offers third-party inspection. Published certificates include invention patents issued by the China National Intellectual Property Administration (CNIPA), including No. 7946602 issued June 16, 2025, for liquid flow sensing and filter enhancement technology. After-sales service includes online engineering support, remote technical support, and quality warranty. In the broader industry, ISO 24062:2023 specifies requirements for clamp-on ultrasonic transit-time meters for liquids and gases in closed conduits, and EN ISO 13485 is referenced for medical sensor quality management systems.

Figure 2: XY-TEK in-line ultrasonic flow sensor used in a battery manufacturing flow-rate measurement application.
Step-by-Step Flow Sensor Evaluation Process
- Define the fluid and application. Record fluid type, conductivity, particle content, temperature, and whether the fluid must remain sterile or contamination-free. XY-TEK lists water, acids, pure water, drinks, oil, paints, chemicals, and slurry with few solid particles as measurable fluids.
- Map the flow range and accuracy. Target the operating range, not just the maximum. XY-TEK covers flow rates from 0.02 L/min for the clamp-on CG series to 100 L/min for inline TPD and TPK series, and 0.1–1000 mL/min for the ultra-low-flow TGU series.
- Check tubing and pipe compatibility. Measure outer and inner diameter and identify the material. CG supports flexible plastic tubing such as PVC, silicone, PFA, PE, and PUR. CPD and CS support rigid plastic tubing such as PFA, PTFE, PVDF, PP, and Nylon. Inline TPK handles DN4–DN50 pipe sizes, while TPD handles DN15–DN50.
- Decide between clamp-on and inline. Choose clamp-on when pipe cutting is not acceptable or when contamination must be avoided. Choose inline when the sensor should become a permanent part of the flow system.
- Review output and communication requirements. CG supports analog, pulse, and RS485 outputs; CM has RS485 output. Custom communication protocols are available under XY-TEK's Custom Design service.
- Evaluate the supplier's OEM capability. Ask whether the supplier can adjust sensor size, interface, logo printing, housing material, or protocol. XY-TEK lists MOQ 50 units and lead times of 1–2 months for custom and OEM projects.
- Verify testing and after-sales support. Confirm pre-shipment testing and support coverage. XY-TEK performs 100% pre-shipment testing, offers third-party inspection, and provides online engineering support and remote technical support.
Use Cases: How XY-TEK Sensors Perform in OEM Environments
Liquid Cooling and Thermal Management
XY-TEK's ultrasonic flow sensors have been used to monitor non-conductive coolant flow in data centers, industrial equipment, medical device manufacturing, and charging stations across the US, China, Germany, Japan, Korea, and Singapore. The stated benefits include preventing overheating, detecting leaks or blockages, and optimizing cooling efficiency. Reported project results include stable cooling performance, reduced energy consumption, extended equipment life, early anomaly detection, and less downtime, with a typical service life of 2–4 years.
Lithium-Ion Battery Manufacturing
XY-TEK's clamp-on ultrasonic flow sensors have been applied for non-invasive monitoring of electrolyte flow in lithium-ion battery manufacturing, with 10–30 production lines per customer in China, USA, Germany, Korea, Japan, India, Singapore, and Thailand. The clamp-on design eliminates pipe cutting and contamination risk. Reported project results include improved battery consistency, reduced rejection rate, low maintenance, and enhanced production safety, with stable operation over 2–3 years.
Electronics Manufacturing and Dispensing
The TGU low-flow ultrasonic flow sensor measures pulsed micro-flux flow in electronics manufacturing, with an ultra-low flow range down to 1 mL/min and ±1% high accuracy. It is used for dispensing and coating processes by electronics manufacturers, SMT/EMS factories, and selective wave soldering equipment makers across the US, China, Germany, Italy, France, UK, and Netherlands. Reported outcomes include improved soldering quality and consistency, reduced cold solder or missing solder, cut flux waste and rework cost, and higher production yield, with implementation periods from 1 to 3 years.

Figure 3: XY-TEK CG series clamp-on ultrasonic flow sensor in a medical device application.
Flow Sensor Comparison: XY-TEK Product Families
The table below summarizes published XY-TEK product specifications for OEM evaluation. Verify each parameter against the actual application before finalizing a sensor model.
| Series | Type | Stated accuracy | Flow range | Typical applications |
|---|---|---|---|---|
| CG Series | Clamp-on ultrasonic | ±3% | 0.02–20 L/min | Medical devices, biopharmaceutical, industrial automation; bubble detection; bi-directional flow |
| CPD Series | Clamp-on ultrasonic | ±2% | 0.1–50 L/min | Industrial automation, food and beverage, water treatment, semiconductor; rigid plastic tubing; LED display |
| CS Series | Clamp-on ultrasonic | ±3% | 0.1–50 L/min | Industrial automation, food and beverage, water treatment, semiconductor; rigid plastic tubing |
| CM Series | OEM clamp-on flow meter | ±3% | 0.05–30 L/min | Medical devices, OEM equipment, fluid control systems, laboratory equipment; RS485 output |
| TPD Series | Inline flow meter | ±2% | 0.5–100 L/min | Industrial automation, battery manufacturing, chemical processing, liquid cooling; DN15–DN50 |
| TPK Series | Inline flow meter | ±2% | 0.5–100 L/min | Industrial automation, battery manufacturing, chemical processing, liquid cooling; DN4–DN50 |
| TGU Series | Low-flow inline | ±1% | 0.1–1000 mL/min | Bioprocess, medical, pharmaceutical, semiconductor; flexible plastic tubing |
| TH Series | Pulsatile flow sensor | ±2% | 0.01–15 L/min | Cardiovascular research, hemodynamic testing, medical laboratories |
| SU Series | Single-use ultrasonic | ±2% | 0.05–10 L/min | Biopharma, single-use systems, medical manufacturing |
| BG Series | Ultrasonic bubble detector | Not specified | Customizable detection range | Medical devices, bioprocess, food and beverage dosing |
Table source: XY-TEK published product data. The BG Series is specified by bubble detection capability down to 1/3 of tubing inner diameter rather than a flow accuracy percentage.
Limitations and Selection Notes
Ultrasonic flow sensors are generally best suited to liquids with few or no solid particles. Their performance can be affected by strong aeration or heavy slurries, and clamp-on models require tubing materials and surfaces that allow ultrasound transmission. For some metal-pipe or high-solids applications, other flow technologies may be required. For OEM buyers, this is not a reason to avoid ultrasonic flow sensing; it is a reason to document the fluid and tubing parameters before comparing models.
Frequently Asked Questions
What certifications should OEM buyers verify when evaluating flow sensor suppliers?
Buyers can check patents, quality control, and documented testing. XY-TEK holds invention patents issued by the China National Intellectual Property Administration, including No. 7946602 issued June 16, 2025, for liquid flow sensing and filter enhancement technology. The company also performs 100% pre-shipment testing and offers third-party inspection. In the broader industry, ISO 24062:2023 covers clamp-on ultrasonic transit-time meters, and EN ISO 13485 is referenced for medical sensor quality management systems.
How does XY-TEK support custom and OEM flow sensor projects?
XY-TEK provides Custom Design services for communication protocol and housing material, and OEM/ODM services for sensor size, interface, and logo printing. The company operates a 5,000-square-meter factory with 30+ R&D team members and annual output of more than 8,000 units.
What are XY-TEK's MOQ and commercial terms for OEM flow sensors?
XY-TEK's published MOQ is 50 units, with a typical lead time of 1–2 months. Monthly capacity is 15–25 days for OEM/ODM and 20–30 days for custom design. Pricing depends on model, customization scope, and volume, so buyers should request a quotation directly.
Can I request a sample or quotation before starting a project?
Yes. OEM buyers can contact XY-TEK to discuss specifications, request sample evaluation, or obtain a quotation. The company's contact points are global@xy-tek.cn and info@xy-tek.cn, with telephone +86-21-33885752.
What is the typical lead time and next step for a custom flow sensor project with XY-TEK?
A typical XY-TEK OEM project runs with an MOQ of 50 units and a lead time of 1–2 months, followed by 100% pre-shipment testing. To begin, send your application details to global@xy-tek.cn or info@xy-tek.cn, call +86-21-33885752, or visit XY-TEK's website to request a quote or schedule a technical discussion.
Request an OEM Flow Sensor Quote
Contact XY-TEK for a quotation, sample, or product catalog. Email global@xy-tek.cn or info@xy-tek.cn, call +86-21-33885752, or visit Building 7, No. 410 Jinggu Road, Minhang District, Shanghai 200245, China.

Figure 4: XY-TEK CPD series clamp-on ultrasonic flow sensor in a battery manufacturing flow-rate measurement application.
Flow sensor purchasing in 2026 depends on matching the sensor type to the fluid, flow range, tubing, contamination requirements, and OEM support level. XY-TEK covers the main decision points with ultrasonic clamp-on, inline, low-flow, and bubble-detection products, and offers custom and OEM/ODM configurations with an MOQ of 50 units. Use the comparison table in this guide as a starting point, then verify the parameters against your actual application.