🌍 Xi'an Tianlong Science and Technology Since 1997 ⭐ 29+ Year Industry Experience ✓ Verified Elite Supplier
✓ Verified Elite Supplier
Menu
Xi'an Tianlong Science and Technology
Verified Elite Supplier
Xi'an Tianlong Science and Technology
China

Annual Output
Nucleic Acid Extraction Reagent Kits: 5 Million+/ Year PCR Reagent Kits: 250,000+/ Year Instruments: 5,000+/ Year (Combined Capacity)
Total Employees
1000+
Business Type
Health & Medicine

Share Us Via

96-Sample Rotary Mixing Automated Nucleic Acid Extraction System

Quantity:
SKU: 7131088560
Model: GeneRotex 96

{{ variable.name }}

{{ value.name }}
GeneRotex 96

96-Sample Rotary Mixing Automated Nucleic Acid Extraction System

The GeneRotex 96 is a high-throughput automated nucleic acid extraction system with rotary mixing and a 1–96 sample capacity. It includes negative pressure, HEPA filtration and UV disinfection for molecular diagnostics, public health laboratories and biomedical research.

Model: GeneRotex 96 | Processing volume: 30–1000 µL | Display: 7-inch color LCD touchscreen

GeneRotex 96 automated nucleic acid extraction system with 7-inch touchscreen
GeneRotex 96 automated nucleic acid extraction system.
SEO Title96-Sample Rotary Mixing Automated Nucleic Acid Extraction System | GeneRotex 96
Meta DescriptionGeneRotex 96 nucleic acid extraction system processes 1-96 samples with rotary mixing, HEPA filtration and UV disinfection for molecular diagnostics labs.
URL Sluggenerotex-96-rotary-nucleic-acid-extraction-system

Product Summary

The GeneRotex 96 processes 1–96 samples per run using rotary mixing. It accepts 96-deep-well plates and customized 6-strip tubes, supports 30–1000 µL processing volumes with a 200 µL sample volume, and offers lysis and elution heating from ambient to 120°C.

Negative pressure, HEPA filtration and UV disinfection support contamination control, while the 7-inch color LCD touchscreen and 510×490×480 mm benchtop body support daily operation.

Key Features

  • 1–96 samples per run: supports batch processing in molecular laboratories.
  • Rotary mixing: helps reduce aerosol generation during extraction.
  • Negative pressure, HEPA filtration and UV disinfection: support contamination control.
  • 30–1000 µL processing volume and 200 µL sample volume: accommodate different protocols.
  • Ambient to 120°C lysis and elution heating: supports programmable temperature steps.
  • Magnetic bead residue <1%: supports magnetic separation performance.

Technical Specifications

ModelGeneRotex 96
Product typeHigh-throughput nucleic acid extractor; rotary mixing extractor
Throughput1–96 samples
Processing volume30–1000 µL
Sample volume200 µL
Mixing methodRotary mixing
Lysis and elution heatingAmbient to 120°C
Magnetic bead residue<1%
Consumables96-deep-well plates and customized 6-strip tubes
Display7-inch color LCD touchscreen
Dimensions510×490×480 mm (W×L×H)
Net weight45 kg

Models and Options

Available model: GeneRotex 96. Consumables: 96-deep-well plates and customized 6-strip tubes. The system supports flexible extraction workflows and programmable protocols.

Materials and Structure

The available source lists structural and safety features rather than housing material. The 510×490×480 mm benchtop unit weighs 45 kg and combines a 7-inch color LCD touchscreen, rotary mixing, negative pressure, HEPA filtration and UV disinfection.

Applications

Molecular diagnostics, public health laboratories and biomedical research. Related applications include disease diagnosis, clinical auxiliary diagnosis, companion diagnostics, health check-ups, blood-borne infectious disease screening, customs inspection and quarantine, and epidemiological analysis.

Related client types include CDC organizations, clinical hospitals, inspection and quarantine stations, customs, research institutes, livestock farming and blood banks.

Customization

Programmable extraction protocols and customized 6-strip tubes support flexible workflows. Other customization details are not specified in the available source.

Case Study

Related project profile: client types include CDC organizations, clinical hospitals, inspection and quarantine stations, customs, research institutes, livestock farming and blood banks. Project values range from US$50,000–200,000, with 3–5 year service durations.

Reported results include customer satisfaction scores, zero accident rate for projects, high detection accuracy, stable performance and compliance with international medical testing standards.

FAQ

What throughput does the GeneRotex 96 support?

It supports 1–96 samples per run, with a 200 µL sample volume and a 30–1000 µL processing volume.

Which consumables can be used with this system?

The specified consumables are 96-deep-well plates and customized 6-strip tubes.

How does the system support contamination control?

The system uses rotary mixing to help reduce aerosol generation and includes negative pressure, HEPA filtration and UV disinfection.

What heating range is available for lysis and elution?

Lysis and elution heating can be set from ambient to 120°C.

What is the magnetic bead residue specification?

The magnetic bead residue is specified as less than 1%.

What are the dimensions and weight of the instrument?

The GeneRotex 96 measures 510×490×480 mm and has a net weight of 45 kg.

Inquiry Information

Address4266 Shanglin Road, Xi’an 710021, China

Image Filename and Alt Suggestions

Image ID16
Suggested filenamegene-rotex-96-rotary-mixing-front.jpg
Suggested alt textGeneRotex 96 automated nucleic acid extraction system with 7-inch color touchscreen and rotary mixing