🌍 Xi'an Tianlong Science and Technology Since 1997 ⭐ 29+ Year Industry Experience ✓ Verified Elite Supplier
✓ Verified Elite Supplier
Menu
Xi'an Tianlong Science and Technology
Verified Elite Supplier
Xi'an Tianlong Science and Technology
China

Annual Output
Nucleic Acid Extraction Reagent Kits: 5 Million+/ Year PCR Reagent Kits: 250,000+/ Year Instruments: 5,000+/ Year (Combined Capacity)
Total Employees
1000+
Business Type
Health & Medicine

Share Us Via

Automated 32-Sample Nucleic Acid Extraction and PCR Setup Workstation PANA3200S

Quantity:
SKU: 3052367269
Model: PANA3200S

{{ variable.name }}

{{ value.name }}

Automated 32-Sample Nucleic Acid Extraction and PCR Setup Workstation PANA3200S

A benchtop workstation that automates sample preparation, nucleic acid extraction and PCR setup in a single 32-sample workflow, with on-deck reagent refrigeration at 4–8°C, liquid level sensing and multiple contamination-control measures.

32 samples per run 5–1000 µL pipetting 4–8°C reagent deck 30–120°C lysis and elution 12.1-inch touchscreen

Product Summary

The PANA3200S is an integrated sample preparation workstation from Tianlong’s automated molecular diagnostics line. It combines lysis, nucleic acid extraction and PCR setup on one deck, so a laboratory can move a 32-sample batch from raw sample to a PCR-ready plate without manual transfer steps between instruments.

This is the core configuration: it does not include PCR centrifugation or PCR tube capping/decapping. It is intended for molecular diagnostics laboratories, public health laboratories and biomedical research groups that already have separate centrifugation and sealing equipment in their workflow.

Key Features

32-sample throughputHandles 32 samples per run with a 200–500 µL sample processing volume — a batch size that matches mid-volume diagnostic and screening workloads.
5–1000 µL pipetting with liquid level sensingOne pipetting channel range covers both small elution volumes and larger reagent transfers, while liquid level sensing monitors aspiration during the run.
4–8°C reagent refrigerationReagents stay cooled on deck throughout the protocol, reducing the need to pre-aliquot small volumes or reload reagents between batches.
30–120°C lysis and elution temperatureA single programmable temperature range covers both heated lysis and elution steps, so different extraction protocols can run on the same deck.
Multiple contamination-control measuresThe workstation is designed with contamination control built into the workflow, which matters when the same bench runs PCR setup after extraction.
12.1-inch touchscreen, Ethernet and USB 2.0Operators run protocols on a large local touchscreen, while Ethernet (TCP/IP) and USB 2.0 ports support data export and network connection.

Technical Specifications

Throughput32 samples
Sample processing volume200–500 µL
Pipetting range5–1000 µL
Lysis and elution temperature30–120°C
Reagent refrigeration4–8°C
PCR centrifugeNo
PCR tube capping / decappingNo
Display12.1-inch touchscreen
InterfacesEthernet (TCP/IP), USB 2.0
Dimensions (W×L×H)732×860×830 mm

Models and Options

Model: PANA3200S — integrated sample preparation, nucleic acid extraction and PCR setup workstation, 32-sample format.

Configuration boundary: the model described on this page is the core configuration without PCR centrifugation and without PCR tube capping/decapping. Laboratories that need those functions should plan for separate equipment, or discuss their workflow with the Tianlong team before ordering.

Materials and Structure

The workstation is a benchtop unit measuring 732×860×830 mm (W×L×H). Its deck integrates a refrigerated reagent position held at 4–8°C, a heated lysis and elution module programmable from 30–120°C, and a pipetting channel covering 5–1000 µL with liquid level sensing. Operator control and protocol monitoring run through the 12.1-inch touchscreen, and Ethernet (TCP/IP) and USB 2.0 interfaces sit on the instrument for network and data-transfer connections.

Detailed wetted-path material specifications are not published in the available documentation; material and compatibility questions for specific consumables should be raised directly with Tianlong.

Applications

The PANA3200S is used in molecular diagnostics, public health laboratories and biomedical research. Documented application areas for Tianlong molecular workflows include:

  • Disease diagnosis and clinical auxiliary diagnosis
  • Companion diagnostics and health check-ups
  • Screening for blood-borne infectious diseases
  • Customs inspection and quarantine testing
  • Epidemiological analysis and public health surveillance

Customization

Published customization options for the PANA3200S are not listed in the available material, so no configuration beyond the documented core specification is claimed here. Requirements around assay protocols, consumable compatibility, Ethernet (TCP/IP) data integration and lab-specific workflow layout should be discussed with Tianlong before an order is placed.

Deployment Profile

Recorded buyer categories for Tianlong molecular diagnostic systems include centres for disease control and prevention, clinical hospitals, inspection and quarantine stations, customs, research institutes, the livestock farming sector and blood banks. Documented project values fall in the US$50,000–200,000 range with 3–5 year programme cycles.

Reported outcomes for these deployments are high detection accuracy, stable instrument performance, compliance with international medical testing standards, and a zero accident rate across projects.

Frequently Asked Questions

What does the PANA3200S automate?

It automates sample preparation, nucleic acid extraction and PCR setup on one deck, so a 32-sample batch moves from sample to PCR setup without manual transfer between separate instruments.

Does it include PCR centrifugation or PCR tube capping and decapping?

No. This is the core configuration, and PCR centrifugation and PCR tube capping/decapping are not part of it. Those steps need separate equipment in your workflow.

How many samples can run in one batch?

32 samples per run, with a sample processing volume of 200–500 µL.

What pipetting range and safeguards does it have?

The pipetting range is 5–1000 µL, and the system uses liquid level sensing to monitor aspiration during the protocol.

How are reagents kept during a run?

Reagents are held on a refrigerated deck at 4–8°C throughout the run.

What temperature range is available for lysis and elution?

Lysis and elution temperature can be set anywhere from 30°C to 120°C.

What are the footprint and connectivity details?

The unit measures 732×860×830 mm (W×L×H), is operated from a 12.1-inch touchscreen, and provides Ethernet (TCP/IP) and USB 2.0 interfaces.

Inquiry Information

For technical questions, configuration confirmation or a quotation on the PANA3200S, contact Xi’an Tianlong Science and Technology Co., Ltd.

Email: inquiry@medtl.com  |  Telephone: +86-29-82682132  |  WhatsApp: +86 18182667606

Address: 4266 Shanglin Road, Xi’an 710021, China  |  Website: www.medtl.net

Image Filename and Alt Suggestions

Panall PANA3200S automated nucleic acid extraction and PCR setup workstation, front view

Existing asset: panall-pana3200s-workstation-front.png

  • panall-pana3200s-workstation-front.png — Alt: Panall PANA3200S automated nucleic acid extraction and PCR setup workstation, front view
  • panall-pana3200s-reagent-deck-4-8c.png — Alt: Refrigerated reagent deck of the PANA3200S workstation held at 4 to 8 degrees Celsius
  • panall-pana3200s-touchscreen-interface.png — Alt: 12.1-inch touchscreen interface on the PANA3200S sample preparation workstation
  • panall-pana3200s-lab-bench-dimensions.png — Alt: PANA3200S installed on a laboratory bench, showing 732 by 860 by 830 mm dimensions
SEO Title: Automated 32-Sample Nucleic Acid Extraction and PCR Setup Workstation PANA3200S
Meta Description: PANA3200S 32-sample automated nucleic acid extraction and PCR setup workstation with 5–1000 µL pipetting, 4–8°C reagent cooling and a 12.1-inch touchscreen.
URL Slug: /products/pana3200s-automated-nucleic-acid-extraction-pcr-setup-workstation