The Genesy 96T is a gradient PCR thermal cycler built around a 96-well Peltier block. It accepts reaction volumes from 0 to 100 microlitres and holds a block temperature range of 4 to 99 degrees Celsius, with a lid controlled between 40 and 110 degrees Celsius.
Its 12-row gradient block spans a 1 to 40 degrees Celsius interval across a 35.5 to 99.5 degrees Celsius gradient range, so one run can screen several annealing temperatures at once. Operators can work in tube control mode or block control mode, and the instrument connects over USB or Ethernet. It is intended for molecular biology laboratories, biomedical research groups and academic research teams that need to optimise PCR protocols before routine use.
| Parameter | Specification |
|---|---|
| Throughput | 96 wells |
| Reaction volume | 0 to 100 microlitres |
| Block temperature range | 4 to 99 degrees Celsius |
| Heating technology | Peltier |
| Gradient block | 12 rows |
| Gradient interval | 1 to 40 degrees Celsius |
| Gradient temperature | 35.5 to 99.5 degrees Celsius |
| Lid temperature | 40 to 110 degrees Celsius |
| Maximum heating rate | At least 5.5 degrees Celsius per second |
| Maximum cooling rate | At least 4.5 degrees Celsius per second |
| Dimensions (W x D x H) | 260 x 400 x 260 mm |
| Weight | 11 kg |
| Connectivity | USB, Ethernet |
| Consumable compatibility | 0.2 mL tubes, strips, 96-well plates |
96-well gradient configuration with a 12-row gradient block, 4 to 99 degrees Celsius block range and 40 to 110 degrees Celsius lid range.
Operate in tube control mode or block control mode to suit the vessel format in use.
Compatible with 0.2 mL tubes, strips and 96-well plates across a 0 to 100 microlitre reaction volume.
The thermal block uses Peltier heating technology, arranged as a 96-well block divided into 12 gradient rows. The heated lid is independently controlled from 40 to 110 degrees Celsius, and the block itself runs from 4 to 99 degrees Celsius. The instrument housing measures 260 x 400 x 260 mm and weighs 11 kg, and data connections are made through USB and Ethernet ports. No further structural or material information is stated in the source documentation.
The Genesy 96T is specified for molecular biology laboratories, biomedical research and academic research, where annealing temperature screening and routine amplification run side by side. In Tianlong project deployments, related molecular diagnostic solutions have been used for disease diagnosis, clinical辅助 diagnosis, companion diagnostics, health check-ups, screening for blood-borne infectious diseases, customs inspection and quarantine, and epidemiological analysis.
Tianlong reports project experience with clients including Centres for Disease Control and Prevention, clinical hospitals, inspection and quarantine stations, customs, research institutes, the livestock farming sector and blood banks, with reported contract values of US$50,000 to 200,000 and project durations of 3 to 5 years. The record cites detection accuracy, stable performance and conformity with international medical testing standards, together with customer satisfaction results and a zero accident rate for delivered projects. This experience is company-level and not a model-specific case study for the Genesy 96T.
Configuration choices documented for this model are the control mode (tube control or block control) and the vessel format used on the block (0.2 mL tubes, strips or 96-well plates). Requirements beyond these documented options are reviewed with the Tianlong technical team through the inquiry channels below; no additional customisation capability is stated in the source materials.
What is the gradient block used for?
The block has 12 gradient rows with a 1 to 40 degrees Celsius interval inside a 35.5 to 99.5 degrees Celsius gradient range, allowing several annealing temperatures to be tested across one 96-well plate.
Which consumables does the Genesy 96T accept?
The instrument is compatible with 0.2 mL tubes, strips and 96-well plates, with a reaction volume range of 0 to 100 microlitres.
What is the difference between tube control and block control?
Both modes are available on this model. Tube control regulates temperature based on the sample tube, while block control regulates based on the block, letting laboratories match the mode to their vessel format and workflow.
How fast are the heating and cooling ramps?
The maximum heating rate is at least 5.5 degrees Celsius per second and the maximum cooling rate is at least 4.5 degrees Celsius per second.
What temperature range does the heated lid cover?
The lid is adjustable from 40 to 110 degrees Celsius, while the block operates between 4 and 99 degrees Celsius.
How is the cycler connected to a laboratory network?
The Genesy 96T provides USB and Ethernet connectivity for connection to laboratory workstations and networks.
Will it fit on a standard laboratory bench?
The unit measures 260 x 400 x 260 mm and weighs 11 kg, so plan bench depth and clearance around the 400 mm dimension.
Which sectors use Tianlong molecular diagnostic equipment?
Documented sectors include clinical diagnostics, disease control, blood banks, inspection and quarantine, animal health and food safety, with products exported to more than 100 countries.
Send your application details, vessel format and throughput requirements to the Tianlong team for configuration guidance.
Recommended capture list and naming for this product page (prefix each file with the product and model):
Existing asset: Tianlong_Genesy_96T_Brochure_Reference.jpg, alt text 'Genesy 96T gradient PCR thermal cycler reference image with 96-well block'.