{{ variable.name }}
PIOON H1 980nm ENT is a portable surgical diode laser platform for minimally invasive ear, nose and throat procedures, combining a 20W 980nm source, PIOON Smart OS and SMA905 fiber delivery in a housing of 225 x 150 x 150 mm.

The PIOON H1 980nm ENT is a compact surgical diode laser designed for minimally invasive ear, nose and throat procedures. The 980nm diode source delivers up to 20W in Continuous Wave or Pulsed mode, with pulse frequency up to 20kHz and variable duty cycle. PIOON Smart OS runs on a 7-inch HD touchscreen and includes 15 clinical presets for common ENT procedures. Laser energy is delivered through 200 micrometre, 300 micrometre or 400 micrometre medical fibers on a standard SMA905 connector. With a net weight of no more than 2kg and an integrated 3350mAh battery, the system can be repositioned between treatment rooms.
The 980nm wavelength interacts with hemoglobin and water, supporting controlled soft tissue incision, ablation and coagulation with effective hemostasis during selected ENT procedures.
Continuous Wave and Pulsed operating modes with pulse frequency up to 20kHz and variable duty cycle let clinicians match parameters to the tissue condition and procedure type.
Smart OS on a 7-inch HD touchscreen provides 15 clinical presets, adjustable power and pulse settings, clear parameter visualization and customizable settings for different clinical needs.
Flexible medical optical fibers support access to narrow anatomical spaces, while ENT handpieces and interchangeable cannulas extend flexibility for endoscopic and minimally invasive techniques.
A net weight of no more than 2kg, a 225 x 150 x 150 mm footprint and an integrated rechargeable battery support flexible use across hospitals, ENT clinics and outpatient rooms.
A high-efficiency cooling system and integrated modular architecture support consistent operation and simplify handling and maintenance in daily clinical use.
| Parameter | Specification |
|---|---|
| Laser type | Medical diode laser |
| Model | H1 980nm ENT |
| Wavelength and power | 980nm / 20W |
| Operating modes | Continuous Wave (CW) / Pulsed |
| Frequency | Up to 20kHz |
| Duty cycle | Variable |
| Display | 7-inch HD touchscreen |
| Control software | Smart OS |
| Fiber connection | Medical fiber 200 micrometre, 300 micrometre, 400 micrometre with standard SMA905 connector |
| Aiming beam | 650nm, less than 2mW |
| Dimensions (L x W x H) | 225 x 150 x 150 mm |
| Net weight | 2 kg or less |
| Battery capacity | 3350mAh |
| Power supply | 18V DC, 5A |

The H1 platform is supplied in the 980nm / 20W ENT configuration. Buyers configure the system by fiber diameter and accessory set, both of which change the working field and procedure fit:
The housing uses ABS+PC with metal components. The metal elements contribute durability, heat dissipation and a professional appearance, while the integrated modular architecture and high-efficiency cooling system support stable operation. The compact internal layout keeps the complete unit within a 225 x 150 x 150 mm envelope at a net weight of no more than 2kg, so it can be carried between consulting rooms and outpatient treatment areas.
H1 980nm ENT supports procedures across four ENT areas, with 15 clinical presets to simplify parameter selection:
PIOON provides OEM cooperation, product training, technical assistance and after-sales services for international distributors. Distributors can specify fiber diameter mix, handpiece and cannula sets, protective eyewear and optional foot pedals to match the procedures they support locally.
PIOON has supported an ongoing ENT program of product demonstrations, professional education and technical exchanges covering diode laser applications in ear, nose and throat procedures, running for at least two years. Participants included ENT clinics, hospital ENT departments, otolaryngologists, medical equipment distributors and surgical laser distribution partners. Activities introduced 450nm and 980nm laser technologies, compatible optical fiber options and potential clinical workflows, and supported technical knowledge sharing among medical professionals and distributors.
The system uses a standard SMA905 connector and is compatible with 200 micrometre, 300 micrometre and 400 micrometre medical optical fibers.
Yes. The unit contains an integrated 3350mAh battery and is powered by an 18V DC, 5A supply, supporting flexible positioning between treatment rooms.
Smart OS runs on the 7-inch HD touchscreen and provides 15 clinical presets, adjustable power and pulse settings, clear visualization of operating parameters and customizable settings for different clinical needs.
Rhinology, laryngology, pharyngology and otology procedures as described in the applications section. Clinical use is subject to local regulatory requirements, approved indications and professional training.
PIOON operates under an ISO 13485:2016 quality management system certified by TUV SUD Product Service GmbH, and holds an EC Certificate for a Full Quality Assurance System under MDD 93/42/EEC Annex II for therapy laser and medical diode laser, plus a CE EMC certificate of conformity. Product registration requirements vary by market and should be confirmed for your territory.
ENT surgical handpieces, interchangeable cannulas, bare fibers, polyimide-coated fibers, protective eyewear and an optional foot pedal.
Contact the PIOON sales team with your target market, required fiber diameters and accessory set so a configuration-specific quotation can be prepared. Pricing, MOQ and lead time are confirmed on request.
Wuhan Pioon Technology Co., Ltd.
12th Floor, Building 1, Innovative Unit, R&D Center Project, Marine World Shipbuilding Park, No. 16, Fozuling 3rd Road, East Lake High-tech Development Zone, 430205, Wuhan, Hubei, China
Email: sales@pioon.com | Mobile: +86 27 87001110 | WhatsApp: +86 18971249550
Clinical applications are subject to local regulatory requirements, approved indications and professional training. Laser systems must be operated by trained medical professionals using wavelength-specific protective eyewear.