Sidecar CDU 200 to 1,200 kW for Modular Data Center Cooling

Quantity:
SKU: 5317649064
Model: DWW30-20C / DWW50-25C; XK-BGCDU-240 / 600 / 1200 / 2500; select each model separately

{{ variable.name }}

{{ value.name }}

Side-Cabinet Liquid Cooling

Sidecar CDU 200 to 1,200 kW for Modular Data Center Cooling

The sidecar CDU series offers 200, 500 and 1,200 kW cooling capacity options in a side-cabinet format. It connects primary cooling to the secondary loop through heat exchange and circulation control for modular data center layouts.

200 / 500 / 1,200 kWSidecar installationSide-cabinet format
Side-cabinet style CDU for sidecar liquid cooling installation
Sidecar CDU in side-cabinet format for row-adjacent liquid cooling.
Installation option: sidecar. Flow rate, differential pressure and supply/return temperature are model-specific and confirmed against project operating conditions.

Product Summary

Sidecar capacity steps for modular data centers

The sidecar CDU series connects primary cooling infrastructure to the secondary loop through heat exchange and circulation control. Sidecar installation places the CDU alongside the IT equipment row for modular layouts and phased deployment. Intelligent controls support operating-status monitoring, and the unit integrates with cold plates, piping and monitoring systems. Pump redundancy is project-specific. Flow rate, differential pressure and supply/return temperature are model-specific and confirmed for the selected model and site conditions.

Key Features

Facts tied to the sidecar series

  • 200 / 500 / 1,200 kW options: Three sidecar capacities cover different modular data center loads.
  • Side-cabinet installation: The sidecar format supports row-adjacent CDU deployment.
  • Heat exchange and circulation control: Connects primary cooling infrastructure to the secondary loop.
  • Intelligent monitoring: Controls support operating-status monitoring and system integration.
  • Stainless steel wetted path: Plate heat exchanger and internal piping are stainless steel on applicable models; confirm grade and wetted materials.
  • Project-specific pump redundancy: Configured to match availability requirements.

Technical Specifications

Catalog specifications and model-specific operating conditions

ParameterSidecar CDU Series
SeriesSidecar CDU
Cooling capacity options200 / 500 / 1,200 kW
InstallationSidecar (side-cabinet)
Flow rateModel-specific (m³/h)
Differential pressureModel-specific (kPa)
Supply / return temperatureModel-specific (°C)
Coolant compatibilityConfirmed per project
Pump redundancyProject-specific
Heat exchanger / internal pipingStainless steel on applicable models; confirm grade and wetted materials
ControlsIntelligent operating-status monitoring
IntegrationCold plates, piping and monitoring systems
Rating basisCatalog specifications; model-specific operating conditions

Models and Options

Select capacity by modular block load

Sidecar optionCooling capacityInstallation
Sidecar 200200 kWSidecar (side-cabinet)
Sidecar 500500 kWSidecar (side-cabinet)
Sidecar 12001,200 kWSidecar (side-cabinet)

Materials and Structure

Wetted-path confirmation is project-specific

Plate heat exchanger and internal piping are stainless steel on applicable models. Confirm exact grade and wetted materials for the selected model and coolant. The side-cabinet structure groups heat exchange, circulation and control functions for sidecar installation. Pump redundancy is project-specific. For site integration, confirm freeze protection, condensation prevention, corrosion protection, noise, electrical supply and local certification requirements.

Applications

Modular and row-adjacent liquid-cooling deployments

Modular Data Centers

Sidecar CDU for prefabricated and phased modular builds.

AI Data Centers

Secondary-loop cooling for high-density AI racks.

HPC

Cold-plate cooling for high-performance computing clusters.

Retrofits

Supports liquid-cooling retrofits and capacity expansion.

Customization

Project-defined configuration

  • Capacity: Select 200 kW, 500 kW or 1,200 kW sidecar options.
  • Pump redundancy: Configured per project.
  • Integration: Cold plates, piping and monitoring systems.
  • Coolant: Compatibility confirmed per project with wetted materials checked.
  • Factory integration: Prefabrication, integrated commissioning and factory testing; the technical agreement defines configuration, delivery and certification scope.

FAQ

Procurement and engineering questions

What cooling capacities are available?

The sidecar series offers 200 kW, 500 kW and 1,200 kW cooling capacity options.

What does sidecar installation mean?

The CDU uses a side-cabinet format alongside the IT equipment row. Confirm aisle, service clearance and layout with engineering.

What flow rate and differential pressure does the CDU provide?

Flow rate and differential pressure are model-specific and confirmed against the selected model, IT load and project operating conditions.

Can pump redundancy be specified?

Yes. Pump redundancy is project-specific and configured to match the availability requirement.

What coolant can be used?

Coolant compatibility is confirmed per project. Wetted materials are checked against the selected model and coolant.

Does the CDU support monitoring?

Intelligent controls support operating-status monitoring and integration with monitoring systems.

What certifications apply?

The manufacturing site holds ISO 9001:2015 and ISO 14001:2015 certificates. The certified scope covers R&D and production of cloud computing liquid cooling equipment and controls. Project-specific certification scope is confirmed separately.

What information is needed for a quote?

Provide modular block load, supply and return temperatures, flow and pressure requirements, coolant, redundancy target, sidecar layout and site conditions.

Inquiry Information

Send project requirements to the Xinke Intelligent Technology team for sidecar capacity selection and layout review.

Email: sales@xinkelcs.com
WhatsApp: +86 18133557330
China hotline: 400-106-2272
Website: www.xinkelcs.com
Address: Guye Economic Development Zone, Tangshan, Hebei, China

Image Filename and Alt Suggestions

Use product, capacity and angle in filenames

Main image filename: cdu-sidecar-200-1200-side-cabinet-front.jpg
Alt text: Side-cabinet style CDU for sidecar liquid cooling installation

Detail image filename: cdu-sidecar-500-side-cabinet-connections.jpg
Alt text: Sidecar CDU side-cabinet piping and connection side

SEO Title: Sidecar CDU 200 to 1,200 kW for Modular Data Center Liquid Cooling

Meta Description: Sidecar CDU options at 200, 500 and 1,200 kW connect primary cooling to the secondary loop. Side-cabinet installation, smart controls and project pump redundancy.

URL Slug: /products/sidecar-cdu-200-500-1200-kw