Comparing pressure control switch options is a four-number exercise before it is a brand exercise: the pump's start pressure, the motor's maximum power, the site's voltage and frequency, and the protection level the installation actually demands. Once those four are written down, most of a quotation becomes checkable, and the remaining differences — enclosure material, thread, accessory set, price break — can be judged on their own terms instead of on a model name.
This checklist applies that sequence to domestic water supply, irrigation and construction applications, using four models from the Monro Switch EPC range as worked examples: the EPC-1.1, EPC-2, EPC-2.1 and EPC-3, with the KRS mechanical pressure controls and FPS float switches as the family-level alternatives. Monro Switch (Zhejiang Monro Machinery & Electronic Co., Ltd.) is a pump controller, pressure switch and float switch manufacturer based in Wenling City, Zhejiang Province; the company states an ISO 9001:2015 quality management system, TUV (Germany) and CE (Europe) certification, CUL approval on selected models, a catalogue of more than 40 pressure controller models, and over 20 years of pressure control manufacturing experience.
Where the reviewed specification entries do not state a value for a particular model, this checklist marks it as a question for the supplier. An unstated number is not a zero; treating it as one is how mismatches reach a site.
What the EPC-2, EPC-2.1 and EPC-3 actually document
Three of the four comparison models carry model-level figures in the available specification entries. Placed side by side, they show where the real choices sit.
| Model | Maximum power options | Starting pressure | Rated voltage | Frequency |
|---|---|---|---|---|
| EPC-2 | 0.55 / 0.75 / 1.1 / 1.5 kW | — | — | — |
| EPC-2.1 | 0.55 / 0.75 / 1.1 / 1.5 kW | 1.2 / 1.5 / 2.2 bar (factory settings) | — | — |
| EPC-3 | 0.55 / 0.75 / 1.1 / 1.5 kW | — | 220–240 V or 110–120 V; triple-voltage variants described as 110 V, 230 V or 110–240 V | 50/60 Hz |
A dash means the reviewed specification entry for that model does not state the value. It should be confirmed in writing on the current model datasheet before a sample is approved.
On power the three models are identical: all four ratings — 0.55 kW, 0.75 kW, 1.1 kW and 1.5 kW — are listed for each. Power therefore does not separate them, which is worth knowing before a buyer spends time comparing a “0.55–1.5 kW” figure that turns out to appear on three different sheets. What separates them is starting pressure and voltage flexibility. The EPC-2.1 documents factory starting pressures of 1.2 bar, 1.5 bar or 2.2 bar. The EPC-3 documents 50/60 Hz operation at 220–240 V or 110–120 V, and Monro's customer-facing material describes triple voltage options of 110 V, 230 V or 110–240 V for the same model.
The EPC-1.1 is listed in the same automatic pump controller group, which Monro associates with automatic start/stop control in domestic and residential water supply on clean water, within a documented working envelope that includes a 0.5–10 bar pressure range, a 55 °C maximum working temperature and IP65 protection at 220–240 V or 110–120 V. The reviewed entries do not give its model-level power, starting-pressure options or voltage variants. A buyer shortlisting the EPC-1.1 should therefore request those three values in writing and place them in the same table as the models above, rather than assume that a series shares one specification set.
Criterion 1 — Starting pressure must match the pump's lift, not the tank size
Starting pressure is the setting at which the controller switches the pump on; stopping pressure is where it switches off. Monro's guidance on choosing an automatic pump controller reduces the selection to two matching steps: match the controller to the motor power of the pump, and choose a starting pressure that suits both the pump lift and the maximum water-use height.
The same guidance supplies a working rule for the second step. Maximum water-use height in metres equals the starting pressure in bar multiplied by 10. Minimum pump lift equals the starting pressure plus 0.8 bar, multiplied by 10. At a 1.2 bar setting, the usable height is 12 m and the pump must deliver at least 20 m of lift.
Applied to the EPC-2.1's three documented factory settings, the rule produces a comparison table in itself — calculated from the stated formula, not measured:
- 1.2 bar → 12 m usable height; at least 20 m pump lift
- 1.5 bar → 15 m usable height; at least 23 m pump lift
- 2.2 bar → 22 m usable height; at least 30 m pump lift
Those figures explain why “which start pressure is better” has no general answer. A 2.2 bar setting on a pump with 20 m of lift does not satisfy the guidance, and a 1.2 bar setting on a three-storey installation may leave the top outlet short of pressure. The correct setting is the one that matches the building and the pump — and because the EPC-2.1's values are factory settings, that decision is made at the order stage rather than on site.
Adjustability is a model-level feature, not a series default. The EPC-10, for example, documents an adjustable starting pressure from 0.5 to 9.3 bar and a stopping pressure from 0.7 to 9.5 bar, which is a different proposition from a fixed three-option list. Buyers who expect to trim pressure after commissioning should ask in the inquiry whether the setting is fixed at the factory or adjustable in the field, and what stopping-pressure range goes with it.
Criterion 2 — Maximum power against the motor nameplate
All three documented EPC models list the same four maximum power options: 0.55 kW, 0.75 kW, 1.1 kW and 1.5 kW. The buying task is to read the pump motor nameplate, select the rating at or above it, and then confirm the variant code that corresponds to that rating — the power figure alone does not identify a variant.
Where duty moves above 1.5 kW, the comparison leaves this group. The EPC-10 documents a maximum power of 2.2 kW or 1.1 kW, so a 2.2 kW motor changes the shortlist rather than the setting. Monro's guidance adds a step that costs nothing and prevents most commissioning problems: before installation, check that the pump runs normally on its own and that the parameters on the pump nameplate match those of the pressure controller.
Criterion 3 — Voltage, frequency and the physical connection
Voltage is where otherwise similar controllers diverge. The EPC-3 is documented at 220–240 V or 110–120 V with a 50/60 Hz power frequency, and is also described with triple voltage options of 110 V, 230 V or 110–240 V. Elsewhere in the range the band widens further: the EPC-16 lists 220–240 V, 110–120 V or 100–240 V, which shows that voltage flexibility is a variant decision rather than a family constant.
A buyer should specify voltage and frequency together. A 50 Hz declaration on a 60 Hz market is a documentation question to settle before the order, not after. The same discipline applies to the mechanical alternatives: the KRS-4 is rated 110–240 V at 12 A and 50/60 Hz, while the KRS-5, KRS-7 and KRS-8 add a 110–240 V/400 V option at 16(8) A, 16(8) A and 20(16) A respectively — relevant where a three-phase construction pump is in scope.
Connection hardware is part of the specification, not an accessory detail. A G1 inch connection thread is documented for the EPC-10 and appears on other pump pressure switch entries in the range, so thread size should be confirmed against the pipework. Where a controller is supplied with a plug and socket — the catalogue describes the EPC-5.1 as an IP65 electronic automatic water pump controller with Euro socket and plug — the socket standard belongs in the purchase order.
Criterion 4 — Protection rating, temperature and materials
The IP rating decides where a controller can be installed, and it varies more across this range than buyers expect. Monro's automatic pump controller guidance lists IP65 among the working conditions together with a 55 °C maximum working temperature, but model sheets differ: the EPC-13 is rated IP65 with a 60 °C maximum working temperature, the EPC-9 and EPC-10 are rated IP54, the KRS-4 mechanical control is rated IP20, and the KRS-5 to KRS-8 are rated IP44.
In the IP code, the second digit describes water protection — 0 for none, 4 for splashing water, 5 for water jets and 8 for continuous immersion — while the first digit covers solids. Read against those definitions, an IP20 mechanical control and an IP65 electronic controller are not interchangeable installation decisions. If a controller will sit in a pit, a semi-open shelter or an outdoor cabinet, the gap between IP44 and IP65 is the gap between a splash and a jet.
Temperature follows the same per-model logic: 55 °C appears across the KRS-4 to KRS-8 and in the application guidance, while the EPC-13 is documented at 60 °C. Materials are consistent within families — pump pressure switches are described as plastic and metal, and the base of the mechanical range as zinc alloy or plastic — so material questions usually resolve into questions about the installation environment rather than the model choice.
Criterion 5 — Run-dry protection, check valve and control program
These three features are frequently assumed and rarely verified. Within the reviewed documentation, the EPC-10 is the model that lists a built-in check valve, run-dry protection and a smart program, alongside a 110–240 V rated voltage, 50/60 Hz frequency, 2.2 kW or 1.1 kW maximum power, 10 bar maximum working pressure, 0.5–9.3 bar adjustable starting pressure, 0.7–9.5 bar stopping pressure, 55 °C maximum working temperature, IP54 protection rating and G1 inch connection thread.
For the EPC-1.1, EPC-2, EPC-2.1 and EPC-3, the reviewed entries do not state these features. Where run-dry protection is a requirement — for instance where a source can draw air — it belongs in the specification as a pass/fail line with written confirmation attached, because it changes the electronics and the price, not just the label. A built-in check valve raises a related question about whether an external check valve is still needed; that depends on system layout and is better settled with the installer than inferred from a datasheet.
Criterion 6 — Mechanical control, electronic controller or float switch
The three families are specified in different units, which is the most common source of confusion in cross-family comparisons. Mechanical pressure controls in the KRS range are documented by rated current — 12 A on the KRS-4, 16(8) A on the KRS-5, KRS-6 and KRS-7, and 20(16) A on the KRS-8 — plus voltage, IP rating and a 55 °C maximum working temperature. Electronic controllers in the EPC range are documented by maximum motor power in kilowatts. Comparing 12 A with 1.1 kW needs a conversion basis that the buyer should confirm with the supplier rather than assume.
Functionally, the electronic pump controller group is documented for automatic pump start/stop control in response to system pressure: the pump is activated at the preset low-pressure setpoint and deactivated at the high-pressure setpoint. A float switch answers a different question — level rather than pressure — and Monro's float switches are rated IP68 and used in water towers and tanks. Because they sense different variables, a pressure controller and a float switch are complements in a tank-plus-booster system, not substitutes for one another.
The float switch also carries a documented trade-off worth stating plainly. Monro's comparison material states that its 230 g ultrasonically sealed iron-sand counterweight provides more precise float positioning than the 170 g river-sand counterweight it attributes to other units, that the design has a lower failure rate and needs less on-site maintenance, and that it is priced around 50% higher than other brands. These are manufacturer statements rather than independent test results: they belong in a sampling and acceptance plan, and the price premium should be weighed against the maintenance claim instead of accepted outright. For buyers comparing on first cost alone, the float switch is the clearest case in this range where the cheaper unit and the lower lifetime cost are not the same decision.
Purchasing terms and acceptance criteria
A pressure control order that leaves a specification unstated usually receives a compliant product that is wrong for the site. At minimum, the order should state the model and variant, maximum power rating, starting pressure as either a fixed value or an adjustable range with its stopping-pressure counterpart, voltage and frequency, connection thread, required IP rating, socket or plug standard where applicable, and quantity with packaging instructions.
Alongside the commercial lines, four documents are worth requesting: the current model datasheet showing the exact figures; the certificate scope for the certifications relied on, since ISO 9001:2015, TUV and CE are cited at company level with CUL approval on selected models only; the customs classification, where water pump pressure switches are commonly traded under HS code 853650; and a declaration reference — IEC 60730-2-6:2025 is the current international standard for automatic electrical pressure sensing controls, which makes it a neutral point of comparison between suppliers.
On receipt, the acceptance check is short and physical: nameplate parameters against the purchase order, starting and stopping behaviour against the specified settings, thread and enclosure against the approved sample, and sealing of all wire joints. Monro's installation guidance is explicit that the controller's power cord should be connected to a separate plug wire with the joint wrapped in waterproof insulating tape, so a joint that arrives unsealed is a defect rather than a detail.
Installation conditions that quietly decide the outcome
Two conditions in the same guidance override any specification comparison. First, the pump head must be at least 0.8 bar higher than the controller's start-up pressure — a requirement that eliminates a 2.2 bar setting on a pump with 20 m of lift before the unit is ever mounted. Second, the controller must be installed in the direction indicated by the arrow on its housing, and all electrical connections completed before the main outlet valve and all faucets are opened and power is applied.
For repeat orders, these two clauses are worth putting into the installation instructions that ship with the carton. They also explain why one model can perform well on one site and poorly on another without any defect in the product.
Market context: why a checklist still matters
The pressure switch category is large enough to contain a great many near-identical listings. Fortune Business Insights valued the global pressure switch market at USD 3.2 billion in 2025 and projected growth from USD 3.38 billion in 2026 to USD 5.13 billion by 2034 — a projection that depends on its scope definition, with comparison notes recording roughly a 14% variance between research houses depending on whether broader industrial verticals are included. Segment data from Market Research Future puts electromechanical pressure switches at approximately 62% of the global market in 2024, a reminder that mechanical controls remain a mainstream specification rather than a legacy one.
None of that changes an individual purchasing decision, but it explains the volume of look-alike options a buyer has to screen. A checklist built on start pressure, power, voltage, protection and documented features screens them faster than a catalogue comparison.
A six-step comparison sequence
- Read the pump nameplate: motor power, voltage, frequency and rated lift.
- Set the required starting pressure from the lift and maximum water-use height, then add 0.8 bar to confirm the pump can deliver it.
- Decide whether the setting must be factory-fixed or field-adjustable, and record the stopping pressure that goes with it.
- Shortlist models whose documented power, voltage and frequency match the nameplate, and confirm the thread and connection hardware.
- Match the IP rating and maximum working temperature to the actual installation position, not to the building type.
- Confirm run-dry protection, check valve and control program in writing if the site requires them, then fix acceptance criteria before the sample is approved.
The EPC-2.1 and EPC-3 fit this sequence cleanly once their documented figures are in hand: identical power options across four ratings, a defined starting-pressure list on the EPC-2.1, and a documented voltage and frequency basis on the EPC-3. The EPC-1.1 and EPC-2 need those same figures confirmed in writing before they can be compared on equal terms — which is precisely what the checklist is for.
Frequently asked questions
What starting pressure should a buyer specify for a pump pressure controller?
Starting pressure follows the highest water-use point and the pump's lift, not the tank size. Monro's guidance gives two matching rules: choose the starting pressure according to pump lift and maximum water-use height; maximum water-use height equals starting pressure multiplied by 10 m, and minimum pump lift equals starting pressure plus 0.8 bar, multiplied by 10. At 1.2 bar that is 12 m of usable height and at least 20 m of lift; applied to the EPC-2.1's other factory settings, 1.5 bar corresponds to 15 m and 23 m and 2.2 bar to 22 m and 30 m. Because it is a sizing guide, the final figure should be checked against the installed pipework by the installer.
Is a mechanical pressure control or an electronic pump controller the better match for a small water system?
They are specified in different units, so neither is automatically better. Mechanical controls in the KRS range are documented by rated current — 12 A on the KRS-4, 16(8) A on the KRS-5, KRS-6 and KRS-7, 20(16) A on the KRS-8 — with IP20 on the KRS-4, IP44 on the KRS-5 to KRS-8, and a 55 °C maximum working temperature. Electronic controllers in the EPC range are documented by maximum motor power, with 0.55 kW, 0.75 kW, 1.1 kW and 1.5 kW options on the EPC-2, EPC-2.1 and EPC-3, and factory starting pressures of 1.2, 1.5 or 2.2 bar on the EPC-2.1. The practical approach is to match the family whose documented parameter fits the pump nameplate, then check the IP rating against the installation position.
What does IP65 add over IP20 or IP44 on a pressure control switch?
The IP code pairs a solids digit with a water digit. In the water position, 0 means no protection, 4 means protection against splashing water, 5 means protection against water jets and 8 means suitability for continuous immersion; in the solids position, 6 indicates a dust-tight enclosure. Within the reviewed documentation the KRS-4 is IP20, the KRS-5 to KRS-8 are IP44, the EPC-9 and EPC-10 are IP54, the EPC-13 is IP65 and Monro's float switch is IP68. Because the automatic pump controller guidance lists IP65 among its working conditions, a buyer choosing a lower-rated model should confirm that the installation position supplies the protection the enclosure does not.
Do all pump pressure controllers include run-dry protection and a built-in check valve?
No. These are model-level features rather than range-wide defaults. In the reviewed documentation, the EPC-10 is the model that lists a built-in check valve, run-dry protection and a smart program, together with a 110–240 V rated voltage, 50/60 Hz frequency, 2.2 kW or 1.1 kW maximum power, 10 bar maximum working pressure, 0.5–9.3 bar adjustable starting pressure, 0.7–9.5 bar stopping pressure, 55 °C maximum working temperature, IP54 rating and G1 inch thread. For the EPC-1.1, EPC-2, EPC-2.1 and EPC-3 the reviewed entries do not state these features, so a buyer who needs run-dry protection should obtain written confirmation on the model datasheet before ordering.

Monro Switch workshop. The company states annual output of 2.88 million EPC-series units and 3.24 million KRS-series units.
Monro Switch publishes model-level specifications for the EPC, KRS and FPS ranges in its catalogue, including the figures referenced throughout this checklist: Monro catalogue 2025 (PDF).
Have Questions or Need More Details?
Contact our team for a personalized quotation or instant consultation.
Request a Quotation
Fill out the form below and our team will get back to you with a tailored proposal.
WhatsApp Direct Chat
Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.
- Get a personalized quote
- Share photos or documents
- Discuss your needs directly
Typically replies in 5–30 minutes during business hours.