Menu

225 MVA Three Winding Substation Power Transformer 230kV to 69kV BESS

Quantity:
SKU: 7755707377
Model: Substation & Power Transformers

{{ variable.name }}

{{ value.name }}
SEO Title: 225 MVA 230kV to 69kV Three Winding Substation Power Transformer for BESS. Meta Description: 225 MVA three-winding transformer stepping 230 kV to 69 kV for utility-scale BESS bidirectional interconnection, built to ANSI/IEEE C57 and IEC 60076. URL Slug: /225mva-three-winding-substation-power-transformer-230kv-69kv-bess

225 MVA Three Winding Substation Power Transformer 230kV to 69kV BESS

Three-winding oil-immersed power transformer for utility-scale battery energy storage grid interconnection · 225 MVA · 230 kV to 69 kV

225 MVA three-winding power transformer 230 kV to 69 kV during factory assembly for a BESS interconnection project

Product Summary

This 225 MVA three-winding substation power transformer links a 69 kV energy storage substation bus to a 230 kV transmission grid. The unit is specified for bidirectional power transfer: it carries power into the battery system while the batteries charge and returns it to the grid while they discharge. It belongs to the Winley Electric high-voltage power transformer range covering 31.5 MVA to 1000 MVA and up to 1000 kV, and is engineered to project-specific electrical, thermal and mechanical requirements, with routine and project-specified factory acceptance tests before shipment.

Key Features

225 MVA Three-Winding Configuration
230 kV on the transmission side and 69 kV on the storage substation side, so one platform serves the BESS interconnection point.
Bidirectional Power Transfer
Specified for charge and discharge cycling, covering both import and export power flow with the same unit.
Low-Loss Grain-Oriented Silicon Steel Core
Targets reduced energy losses and controlled operating temperatures through continuous cycling duty.
Precision-Wound Copper or Aluminum Windings
Low load losses with short-circuit withstand capability for a high-capacity grid connection.
ONAN ONAF OFAF ODAF Cooling Options
Cooling class is selected to match the charge and discharge duty cycle and the site ambient conditions.
Integrated Monitoring and Protection
Buchholz relay, pressure relief device and winding and oil temperature indicators support safe operation and simplified maintenance.

Technical Specifications

Rated capacity225 MVA, three-winding
Voltage ratio230 kV to 69 kV
Winding configurationThree-winding; two-winding and auto-transformer configurations available
Cooling methodsONAN / ONAF / OFAF / ODAF
CoreGrain-oriented silicon steel
ConductorsCopper or aluminum, precision wound
Tap changingOn-load tap changer (OLTC) or de-energized tap changer (DETC)
Protection accessoriesBuchholz relay, pressure relief device, winding and oil temperature indicators
StandardsANSI/IEEE C57, CSA C88, AS 60076, IEC 60076, DOE efficiency
Factory testingRoutine and project-specified acceptance tests with serialized reports
Typical lead time10 to 20 weeks, depending on capacity, voltage class and customization
Warranty24 months from B/L date, extendable up to 5 years on project request

Models and Options

The three-winding configuration can be delivered as a two-winding or auto-transformer arrangement when the project single-line diagram calls for it, in three-phase or single-phase format. Tap changing is available as OLTC or DETC, and the unit can be supplied with conservator or sealed-tank construction, porcelain or polymer bushings, HV and LV air terminal chambers, throat connections and a tank footprint matched to the civil layout of the storage site.

Materials and Structure

The magnetic circuit uses grain-oriented silicon steel; windings are precision wound in copper or aluminum; the tank, cooling equipment and oil-immersed cooling system are built around the thermal and mechanical duty of the site. Protection and monitoring devices are integrated into the structure so that gas accumulation, tank pressure and winding and oil temperatures can be supervised during unattended operation.

Applications

Utility-scale battery energy storage grid interconnection, renewable energy integration, peak shaving, grid stabilization, transmission substations and utility grid capacity projects where a 230 kV to 69 kV transformation stage is required.

Customization

Winding conductor material, cooling class, tap changer type, bushing type, tank dimensions, protection and monitoring package, compliance standard set and the factory acceptance test plan are defined per project. Drawings, accessory selection and test schedules are agreed before production starts.

Case Study

Project: one 225 MVA, 230 kV to 69 kV three-winding power transformer for a utility-scale BESS grid interconnection in the United States. The unit connects the 69 kV energy storage substation system to the 230 kV transmission grid and supports bidirectional power transfer during battery charging and discharging, for an expected 30-year service life.

Scope covered large-scale energy storage integration, peak shaving and grid stabilization. The flexible cooling configuration accommodates varying power demand across charge and discharge cycles; the electrical and thermal design targets reduced energy losses and controlled operating temperatures; integrated monitoring and protection support safe operation and simplified maintenance.

FAQ

Can the transformer handle bidirectional power flow?

Yes. The unit is specified for bidirectional power transfer, covering charging and discharging operation of the battery system.

Which standards can the design follow?

ANSI/IEEE C57, CSA C88, AS 60076, IEC 60076 and DOE efficiency requirements, as named in the project specification.

What is the typical lead time?

10 to 20 weeks depending on capacity, voltage class and custom specifications.

Are factory tests documented?

Every unit goes through routine and project-specified factory acceptance tests with serialized test reports prior to shipment.

What protection devices are available?

Buchholz relay, pressure relief device and winding and oil temperature indicators, integrated in the monitoring package.

What warranty applies?

24 months from the Bill of Lading date as standard, extendable up to 5 years on project request.

Inquiry Information

Send the single-line diagram, rated capacity, voltage class, cooling preference, applicable standard and site conditions for a project-specific quotation.

Xiamen Winley Electric Co.,Ltd · No. 99 Yilan Road, Siming, Xiamen, Fujian, China

Email: steven@winley-electric.com · Tel: 86-18650108051 · WhatsApp: +8618650108051

Management systems certified to ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018, scope covering the full product range.

Image Filename and Alt Suggestions

Side view of the 225 MVA BESS interconnection transformer tank and cooling equipment

225mva-three-winding-power-transformer-230kv-bess-tank-side.jpg

HV bushing arrangement on the 230 kV three-winding substation power transformer for a storage project

225mva-three-winding-power-transformer-230kv-bess-bushing-detail.png