{{ variable.name }}

The 50 kVA model of the S11-M series, using a corrugated sheet steel tank that handles oil expansion without a conservator, so the oil stays sealed and the unit runs quietly at low no-load loss.
S11-M-50 sits mid-range in the S11-M hermetically sealed oil-immersed distribution transformer series. It is the rating most often chosen for township distribution branches, commercial compounds and plant feeders where one unit has to carry a mixed load without a large footprint in the network. A corrugated sheet steel tank replaces the oil conservator: the flexible panels follow the temperature-induced oil volume change while the oil itself remains sealed against moisture and oxidation. Rated 50 kVA at 50 Hz and offered in 15 kV or 30 kV voltage class, the unit is built as an outdoor distribution transformer with low no-load loss and quiet running, and its sealed construction greatly cuts inspection and servicing work.
Corrugated Sheet Steel Tank
Flexible panels absorb temperature-induced oil expansion and contraction, so the design works without an oil conservator at all.
50 kVA Mid-Range Rating
A distribution capacity that fits township feeders, commercial compounds and plant-level branches, running on 50 Hz networks.
No Oil Top-Up Routine
Because the oil is enclosed, oxidation and moisture intrusion are avoided and there is no conservator oil level to inspect and refill.
Silicon Steel and Copper
Silicon steel sheet core and copper winding are the specified materials behind the series' stable running performance.
Low No-Load Loss, Low Noise
Energy lost while the transformer is energised but lightly loaded stays low, and acoustic output is kept quiet for built-up areas.
Outdoor Environmental Tolerance
Sealed construction is specified for long-term outdoor service, including humid and tropical project climates.
| Model | S11-M-50 |
|---|---|
| Rated capacity | 50 kVA |
| Voltage class | 15 kV / 30 kV (confirmed per order) |
| Frequency | 50 Hz |
| Transformer type | Fully sealed oil-immersed distribution transformer |
| Tank construction | Corrugated sheet steel tank, no oil conservator |
| Core material | Silicon steel sheet |
| Winding material | Copper |
| Insulating medium | Transformer oil, hermetically sealed |
| Operating environment | Outdoor power distribution |
| HS code | 8504210000 |
Loss figures, impedance and dimensional drawings are project-specific and are confirmed before manufacture rather than published as series constants.
Capacity (25, 50 or 400 kVA) and voltage class (15 kV or 30 kV) are selected from the series options when the order is placed. Send the load schedule and system voltage and the matching configuration is confirmed before manufacture. Foshan TE Electric also supplies high and low voltage switchgears, distribution boxes and bus ducts, and provides one-stop EPC general contracting for power engineering projects.
An electrical contractor in Rwanda purchased 13 units of S11-M series transformers for voltage step-down and power distribution on the local grid.
Why is a corrugated tank used instead of a separate conservator?
The corrugated panels flex as the oil warms and cools, taking up the volume change inside the same sealed enclosure. That removes the conservator and keeps moisture and air away from the oil.
What kind of load suits a 50 kVA unit?
Township distribution branches, grouped commercial compounds and plant feeders are typical. Confirm with your load calculation before choosing between 25, 50 and 400 kVA.
Does the transformer need regular oil level checks?
There is no conservator oil level to inspect and top up. Sealed construction greatly reduces inspection and servicing work, which is why the series is used in remote and off-grid projects.
Which voltage classes can be ordered?
The S11-M series is offered in 15 kV and 30 kV class. The class that matches your distribution system is confirmed with the order.
Is the unit suitable for tropical project climates?
Sealed construction is specified for long-term outdoor service, and tropical climate adaptability is recorded among the reported benefits of the Rwanda installation.
What is the HS code for customs paperwork?
The series is classified under HS code 8504210000, which can be quoted directly on shipping documents.
Tell us the load schedule, system voltage and site climate and we will confirm the matching 50 kVA configuration.