Menu

Genesy 96T Gradient PCR Thermal Cycler for 96-Well Plate Protocols

Quantity:
SKU: 2587187478
Model: Genesy 96T

{{ variable.name }}

{{ value.name }}
SEO Title

Genesy 96T Gradient PCR Thermal Cycler for 96-Well Plate Labs

Meta Description

Genesy 96T gradient PCR thermal cycler: 96-well Peltier block, 12-row gradient, tube and block control modes, USB and Ethernet for molecular labs.

URL Slug

/genesy-96t-gradient-pcr-thermal-cycler

Product Listing Title

Genesy 96T Gradient PCR Thermal Cycler for 96-Well Plate Protocols

Genesy 96T Gradient PCR Thermal Cycler

A 96-well Peltier thermal cycler with a 12-row gradient block, tube and block control modes, and USB/Ethernet connectivity for protocol optimisation in molecular biology laboratories.

96 wells12-row gradient0 to 100 microlitre volumePeltier heatingUSB and Ethernet
Genesy 96T gradient PCR thermal cycler reference image with 96-well block
Genesy 96T gradient PCR thermal cycler, 96-well format, 260 x 400 x 260 mm, 11 kg.

Product Summary

The Genesy 96T is a gradient PCR thermal cycler built around a 96-well Peltier block. It accepts reaction volumes from 0 to 100 microlitres and holds a block temperature range of 4 to 99 degrees Celsius, with a lid controlled between 40 and 110 degrees Celsius.

Its 12-row gradient block spans a 1 to 40 degrees Celsius interval across a 35.5 to 99.5 degrees Celsius gradient range, so one run can screen several annealing temperatures at once. Operators can work in tube control mode or block control mode, and the instrument connects over USB or Ethernet. It is intended for molecular biology laboratories, biomedical research groups and academic research teams that need to optimise PCR protocols before routine use.

Key Selling Points

  • 12-row gradient block (1 to 40 degrees Celsius interval): compare multiple annealing temperatures in a single plate run, reducing the number of repeat experiments needed to lock a protocol.
  • 96-well throughput with 0 to 100 microlitre reaction volume: run full 96-well plates, strips or single 0.2 mL tubes on one block, so low-volume checks and full-plate runs share the same instrument.
  • Tube control and block control modes: choose the control mode that matches the vessel type being used, which helps keep results consistent when switching between tubes, strips and plates.
  • Peltier heating with maximum heating rate of at least 5.5 degrees Celsius per second and maximum cooling rate of at least 4.5 degrees Celsius per second: shortens ramp time between temperature steps in multi-step cycling programmes.
  • USB and Ethernet connectivity: connect the cycler to a laboratory workstation network for run management alongside other instruments.
  • Compact bench footprint of 260 x 400 x 260 mm at 11 kg: fits on standard laboratory benches where bench space is limited.

Technical Specifications

ParameterSpecification
Throughput96 wells
Reaction volume0 to 100 microlitres
Block temperature range4 to 99 degrees Celsius
Heating technologyPeltier
Gradient block12 rows
Gradient interval1 to 40 degrees Celsius
Gradient temperature35.5 to 99.5 degrees Celsius
Lid temperature40 to 110 degrees Celsius
Maximum heating rateAt least 5.5 degrees Celsius per second
Maximum cooling rateAt least 4.5 degrees Celsius per second
Dimensions (W x D x H)260 x 400 x 260 mm
Weight11 kg
ConnectivityUSB, Ethernet
Consumable compatibility0.2 mL tubes, strips, 96-well plates

Models and Options

Genesy 96T

96-well gradient configuration with a 12-row gradient block, 4 to 99 degrees Celsius block range and 40 to 110 degrees Celsius lid range.

Control mode option

Operate in tube control mode or block control mode to suit the vessel format in use.

Vessel formats

Compatible with 0.2 mL tubes, strips and 96-well plates across a 0 to 100 microlitre reaction volume.

Materials and Structure

The thermal block uses Peltier heating technology, arranged as a 96-well block divided into 12 gradient rows. The heated lid is independently controlled from 40 to 110 degrees Celsius, and the block itself runs from 4 to 99 degrees Celsius. The instrument housing measures 260 x 400 x 260 mm and weighs 11 kg, and data connections are made through USB and Ethernet ports. No further structural or material information is stated in the source documentation.

Applications

The Genesy 96T is specified for molecular biology laboratories, biomedical research and academic research, where annealing temperature screening and routine amplification run side by side. In Tianlong project deployments, related molecular diagnostic solutions have been used for disease diagnosis, clinical辅助 diagnosis, companion diagnostics, health check-ups, screening for blood-borne infectious diseases, customs inspection and quarantine, and epidemiological analysis.

Project Experience

Tianlong reports project experience with clients including Centres for Disease Control and Prevention, clinical hospitals, inspection and quarantine stations, customs, research institutes, the livestock farming sector and blood banks, with reported contract values of US$50,000 to 200,000 and project durations of 3 to 5 years. The record cites detection accuracy, stable performance and conformity with international medical testing standards, together with customer satisfaction results and a zero accident rate for delivered projects. This experience is company-level and not a model-specific case study for the Genesy 96T.

Customization

Configuration choices documented for this model are the control mode (tube control or block control) and the vessel format used on the block (0.2 mL tubes, strips or 96-well plates). Requirements beyond these documented options are reviewed with the Tianlong technical team through the inquiry channels below; no additional customisation capability is stated in the source materials.

FAQ

What is the gradient block used for?

The block has 12 gradient rows with a 1 to 40 degrees Celsius interval inside a 35.5 to 99.5 degrees Celsius gradient range, allowing several annealing temperatures to be tested across one 96-well plate.

Which consumables does the Genesy 96T accept?

The instrument is compatible with 0.2 mL tubes, strips and 96-well plates, with a reaction volume range of 0 to 100 microlitres.

What is the difference between tube control and block control?

Both modes are available on this model. Tube control regulates temperature based on the sample tube, while block control regulates based on the block, letting laboratories match the mode to their vessel format and workflow.

How fast are the heating and cooling ramps?

The maximum heating rate is at least 5.5 degrees Celsius per second and the maximum cooling rate is at least 4.5 degrees Celsius per second.

What temperature range does the heated lid cover?

The lid is adjustable from 40 to 110 degrees Celsius, while the block operates between 4 and 99 degrees Celsius.

How is the cycler connected to a laboratory network?

The Genesy 96T provides USB and Ethernet connectivity for connection to laboratory workstations and networks.

Will it fit on a standard laboratory bench?

The unit measures 260 x 400 x 260 mm and weighs 11 kg, so plan bench depth and clearance around the 400 mm dimension.

Which sectors use Tianlong molecular diagnostic equipment?

Documented sectors include clinical diagnostics, disease control, blood banks, inspection and quarantine, animal health and food safety, with products exported to more than 100 countries.

Inquiry Information

Send your application details, vessel format and throughput requirements to the Tianlong team for configuration guidance.

Image Filename and Alt Suggestions

Recommended capture list and naming for this product page (prefix each file with the product and model):

  • genesy-96t-gradient-pcr-thermal-cycler-front.png
  • Alt: Genesy 96T gradient PCR thermal cycler front view with closed heated lid
  • genesy-96t-twelve-row-gradient-block.png
  • Alt: Open 96-well block showing the 12 gradient rows of the Genesy 96T
  • genesy-96t-usb-ethernet-ports.png
  • Alt: Rear panel of the Genesy 96T showing USB and Ethernet ports
  • genesy-96t-bench-installation.png
  • Alt: Genesy 96T thermal cycler installed on a molecular biology laboratory bench

Existing asset: Tianlong_Genesy_96T_Brochure_Reference.jpg, alt text 'Genesy 96T gradient PCR thermal cycler reference image with 96-well block'.