The Gentier 96E is a 96-well real-time PCR system from Tianlong, built on a Peltier thermal block with six fluorescence channels. It runs 1-96 samples per plate, completes a full fluorescence scan in about 7 seconds, and combines fast heating and cooling with temperature control accuracy of ≤0.1°C. A 1-40°C gradient supports annealing optimisation in a single run, and the 10.4-inch touchscreen allows standalone operation or PC control.
Six detection channels support multiplex qPCR in a single run, and all channels are read in a 7-second fluorescence scan.
Peltier heating reaches ≥6.1°C/s and cooling reaches ≥5.0°C/s, shortening thermal protocols between denaturation and annealing steps.
Block temperature is controlled to within 0.1°C, supporting reproducible quantification and melting curve analysis.
A gradient interval of 1-40°C lets you screen annealing temperatures across the block within one experiment.
The integrated 10.4-inch touchscreen runs the instrument at the bench, or the system can be operated from a PC.
355×475×484 mm (W×L×H) with a net weight of 30 kg, sized for a standard 96-well laboratory bench.
| Parameter | Specification |
|---|---|
| Model | Gentier 96E |
| Type | 96-Well Real-Time PCR System; Multiplex qPCR System |
| Throughput | 1-96 samples |
| Fluorescence channels | 6 |
| Fluorescence scanning time | 7 s |
| Heating method | Peltier |
| Maximum heating rate | ≥6.1°C/s |
| Maximum cooling rate | ≥5.0°C/s |
| Temperature control accuracy | ≤0.1°C |
| Gradient interval | 1-40°C |
| Display | 10.4-inch touchscreen |
| Dimensions (W×L×H) | 355×475×484 mm |
| Weight | 30 kg (net) |
| Operating environment | Temperature 10°C-30°C; relative humidity 20%-85%, non-condensing |
| Altitude / pressure | 0 m-2000 m; 85.0 kPa-106.0 kPa |
| Matched equipment | Automated nucleic acid extractors |
The Gentier 96E is the 96-well, 6-fluorescence-channel configuration covered on this page. Tianlong's real-time PCR range also includes the Gentier 96 Series, Gentier Sp96 Series, Gentier 48 Series, Gentier Mini Series and Gentier X3 Series; block format, channel count and throughput differ by series and should be confirmed against the current datasheet before ordering.
The instrument is a bench-top unit measuring 355×475×484 mm (W×L×H) with a net weight of 30 kg. Thermal cycling is driven by a Peltier block, and a 10.4-inch touchscreen is integrated into the instrument for standalone operation, with PC operation available as an alternative control route.
Detailed enclosure material specifications were not provided in the source documentation and are confirmed on request.
Clinical molecular diagnostics, infectious disease testing, genetic testing and pathogen screening in hospital and public health laboratories; gene expression and SNP analysis in biomedical research and pharma/biotech settings; food safety and environmental testing. The platform is listed with automated nucleic acid extractors as matched equipment, supporting an extraction-to-qPCR workflow.
Configuration is confirmed against your assay before an order is placed: sample throughput, fluorescence channel requirements and the choice of standalone or PC operation. Reagent kits from the same manufacturer's molecular diagnostics range can be matched to your target. State your application and workflow when requesting a quotation so the block format and channel setup can be verified.
Reported project profile: deployments in the US$50,000-200,000 range with 3-5 year supply relationships, serving CDC-type public health centres, clinical hospitals, inspection and quarantine stations, customs laboratories, research institutes, blood banks and the livestock sector. Typical uses include disease diagnosis, blood-borne infectious disease screening and epidemiological analysis.
The system is specified for 1-96 samples, so a single run can cover anything from a small batch to a full 96-well plate.
Yes. Six fluorescence channels are available, and a full fluorescence scan takes 7 seconds, which supports multiplex detection alongside quantitative and melting curve analysis.
Yes. A 10.4-inch touchscreen is integrated into the instrument for standalone operation, and PC operation is also supported.
The gradient interval is 1-40°C and temperature control accuracy is ≤0.1°C, with maximum heating and cooling rates of ≥6.1°C/s and ≥5.0°C/s respectively.
Ambient temperature 10°C-30°C, relative humidity 20%-85% non-condensing, and altitude 0-2000 m corresponding to 85.0 kPa-106.0 kPa.
The unit measures 355×475×484 mm (W×L×H) and weighs 30 kg net.
Pricing, order quantity and delivery are quoted per configuration and destination. Contact the manufacturer with your application, throughput and channel requirements.
Manufacturer background: Xi'an Tianlong Science and Technology Co., Ltd., founded 1997, total facility area 46,500 m², 1000+ employees and a 300+ member R&D team; products exported to 100+ countries serving 9,000+ customers, with 90+ medical device registrations in China and 300+ international certifications and regulatory approvals including CE, FDA-related and KFDA-related credentials, as reported by the manufacturer.
| Filename | Alt Text |
|---|---|
| gentier-96e-real-time-pcr-system-front-96-well.jpg | Gentier 96E real-time PCR system front view with the 96-well sample block |
| gentier-96e-touchscreen-standalone-operation.jpg | 10.4-inch touchscreen interface used for standalone operation of the Gentier 96E |
| gentier-96e-fluorescence-channels-multiplex-assay.jpg | Six-channel fluorescence detection setup of the Gentier 96E during a multiplex qPCR run |
| gentier-96e-lab-bench-clinical-diagnostics.jpg | Gentier 96E qPCR instrument installed on a clinical diagnostics laboratory bench |
| gentier-96e-rear-ports-pc-connection-detail.png | Rear connection panel of the Gentier 96E for PC operation and data transfer |