{{ variable.name }}

Drawable functional units and a common busbar system let each circuit be withdrawn without interrupting the main busbar supply, supporting quick replacement and expansion.
The rated short-time withstand current is 50kA/1s for short-circuit breaking in 0.4kV networks.
Rated current up to 4000A at 0.4kV and 50/60Hz supports incoming, outgoing, bus-tie control and circuit protection.
The 600×1000×2200mm cabinet supports a compact layout. The Mongolia cable car station case notes compact layout and low temperature resistance for 22 sets over a 10-year design duration.
Standard protection is IP40 for indoor installation with natural ventilation. A higher protection class can be customized per site requirements.
| Parameter | Specification |
|---|---|
| Model | GCK 600×1000×2200 |
| Rated voltage | 0.4kV |
| Rated frequency | 50/60Hz |
| Rated current | Up to 4000A |
| Rated short-time withstand current | 50kA/1s |
| Protection class | IP40, higher protection class customizable per site requirements |
| Dimensions | 600×1000×2200mm |
| Cooling method | Natural ventilation |
| Installation | Indoor |
| Structure | Draw-out switchgear with common busbar system |
The referenced model is GCK 600×1000×2200 with 0.4kV rated voltage and rated current up to 4000A. Circuit configuration and withdrawable units can be arranged for incoming, outgoing, bus-tie control and protection. IP40 is standard; a higher protection class can be customized per site requirements. Price, MOQ and lead time are not stated in the source data and should be confirmed by inquiry.
The cabinet uses cold-rolled steel sheet, copper busbar, molded case circuit breaker components and insulating epoxy parts. Drawable functional units are combined with a common busbar system for independent circuit withdrawal. The structure is compact and uses natural ventilation for indoor installation.

The GCK cabinet is used for incoming, outgoing, bus-tie control and circuit protection in 0.4kV networks. Sectors include industrial plants, commercial buildings, data centers, photovoltaic power stations, power grids and infrastructure projects.
Protection class can be customized above standard IP40 per site requirements. Circuit configuration, withdrawable functional units and system expansion can be arranged for project needs. Confirm specific site conditions and protection requirements with the supplier.
Client type: Infrastructure project contractor
Country: Mongolia
Quantity: 22 sets
Application: Power supply for Ulaanbaatar Yarmag cable car station
Duration: 10 years
Result: Stable power guarantee for cable car system
Highlight: Low temperature resistance, compact layout, IEC standard
The switchgear is rated for 0.4kV and 50/60Hz operation.
The rated current is up to 4000A.
The rated short-time withstand current is 50kA/1s.
Each circuit can be independently withdrawn without interrupting the main busbar supply, supporting quick component replacement and expansion.
Standard protection is IP40 for indoor installation with natural ventilation. A higher protection class can be customized per site requirements.
The Mongolia cable car station case reports low temperature resistance, compact layout and IEC standard for 22 sets over a 10-year design duration. Exact ambient temperature limits are not stated in the source data; confirm site conditions with the supplier.
The model measures 600×1000×2200mm and uses cold-rolled steel sheet, copper busbar, molded case circuit breaker components and insulating epoxy parts.
Contact: Samantha, Sales Manager
Email: samantha@teelectric.com
TEL: +86 13923783341
WhatsApp: +86 13360330142
Address: 16#, Fuheng Road, Hecheng Street, Gaoming District, Foshan, Guangdong, China
Foshan TE Electrical Co., Ltd. operates under ISO9001, ISO14001 and ISO45001 management systems. Share your project voltage, current, circuit quantity and site protection requirements for a suitable GCK configuration.