Integrated 96-Sample Nucleic Acid Extraction And PCR Setup Workstation

Quantity:
SKU: 8222411810
Model: PANA9600X

{{ variable.name }}

{{ value.name }}

Integrated 96-Sample Nucleic Acid Extraction And PCR Setup Workstation

Tianlong PANA9600X integrated nucleic acid extraction and PCR setup workstation

PANA9600X integrated sample preparation workstation

Product Summary

The PANA9600X is an integrated sample preparation workstation that brings tube decapping and capping, barcode scanning, sample loading, magnetic-bead nucleic acid extraction and PCR setup onto one platform. It processes 1 to 96 samples per run through four independent loading channels and supports up to four PCR systems per run, giving molecular laboratories a continuous, traceable path from primary tube to PCR setup.

Key Features

Four independent loading channels

Four sample loading channels with a 5-1000 µL pipetting range handle batch sizes from a single sample up to a full 96-sample run.

Magnetic bead extraction

Magnetic beads with rotary mixing are used for nucleic acid extraction, with lysis and elution temperature adjustable from 35 to 120 °C.

PCR reagent bay at 4-8 °C

PCR reagents are held at 4-8 °C on the instrument, keeping master mix cold between setup steps.

Up to four PCR systems per run

One workstation can prepare for up to four PCR systems per run, consolidating downstream setup in high-throughput laboratories.

Sample-to-PCR traceability

Barcode scanning combined with LIS connectivity over Ethernet and USB links each primary sample to its PCR setup record.

12.1-inch touchscreen

Run setup and monitoring are handled on a 12.1-inch touchscreen at the instrument.

Technical Specifications

ParameterSpecification
ModelPANA9600X
Product typeIntegrated sample preparation workstation; 96-sample extraction workstation
Sample capacity1-96 samples per run
Sample loading channels4
Pipetting range5-1000 µL
Extraction methodMagnetic beads with rotary mixing
Lysis and elution temperature35-120 °C
PCR reagent refrigeration4-8 °C
Display12.1-inch touchscreen
InterfacesEthernet, USB
Dimensions (L×W×H)1370×810×960 mm
Net weight235 kg

Models And Options

This page covers the PANA9600X configuration. Within a single unit, laboratories select the sample batch size (1 to 96), decide how the four loading channels are used across a run, and connect up to four PCR systems per run. Laboratory information system integration is available through the Ethernet and USB interfaces. Tianlong also lists the PANA3200S+ and Aurora PANA X6 automated sample processing, extraction and PCR setup workstations as separate platforms in its portfolio.

Materials And Structure

The PANA9600X is an integrated benchtop-scale system with an L×W×H footprint of 1370×810×960 mm and a net weight of 235 kg, so lab planning should allow for a dedicated installation area with rear access for cabling. Operator interaction is concentrated on the 12.1-inch touchscreen, and data connection is made through Ethernet and USB ports.

Applications

The workstation is built for molecular diagnostics, public health laboratories and biomedical research. Documented application areas include disease diagnosis, clinical auxiliary diagnosis, companion diagnostics, health check-ups, screening for blood-borne infectious diseases, customs inspection and quarantine, and epidemiological analysis.

Molecular diagnosticsPublic health laboratoriesBiomedical researchBlood banksCustoms and quarantineResearch institutesLivestock sector

Case Study

Reported deployments cover centres for disease control and prevention, clinical hospitals, inspection and quarantine stations, customs, research institutes, the livestock farming sector and blood banks. Reported project values range from US$50,000 to 200,000, with project durations of 3 to 5 years. Reported outcomes include high detection accuracy, stable performance, compliance with international medical testing standards and a zero accident rate for projects.

FAQ

How many samples can the PANA9600X process in one run?

Sample capacity is 1 to 96 per run, so the same unit can handle a single urgent sample or a full 96-sample plate.

What is the pipetting range and how many channels are there?

The workstation has four sample loading channels covering a pipetting range of 5-1000 µL.

Which extraction chemistry does it use?

Extraction is based on magnetic beads with rotary mixing, with adjustable lysis and elution temperatures from 35 to 120 °C.

Can PCR reagents stay cold during setup?

Yes. The PCR reagent position is refrigerated at 4-8 °C while setup is in progress.

How many PCR systems can one run prepare for?

Up to four PCR systems per run are supported.

How is sample-to-PCR traceability maintained?

Tube barcode scanning is combined with LIS connectivity through the Ethernet and USB interfaces.

What installation space is required?

Plan for 1370×810×960 mm (L×W×H) and a net weight of 235 kg, plus access for Ethernet and USB connections.

Which laboratories typically use this workstation?

Molecular diagnostics, public health laboratories and biomedical research groups, including CDC networks, hospitals, blood banks, customs and quarantine stations, and research institutes.

Inquiry Information

Xi'an Tianlong Science and Technology Co., Ltd.

Email: inquiry@medtl.com

Telephone: +86-29-82682132

WhatsApp: +86 18182667606

Address: 4266 Shanglin Road, Xi'an 710021, China

Website: www.medtl.net

Founded in 1997, with a 300+ member R&D team, products exported to 100+ countries and the PANA9600X supported as part of an instrument, reagent and software portfolio.

SEO Title: Integrated 96-Sample Nucleic Acid Extraction and PCR Setup WorkstationMeta Description: PANA9600X automates decapping, barcode scanning, magnetic bead extraction and PCR setup for 1-96 samples, with 4-channel pipetting and LIS traceability.URL Slug: /pana9600x-integrated-nucleic-acid-extraction-pcr-setup-workstationImage suggestion 1: pana9600x-integrated-workstation-front.png - Tianlong PANA9600X workstation front view with 12.1-inch touchscreenImage suggestion 2: pana9600x-four-channel-pipetting.png - Four-channel pipetting arm loading samples on the PANA9600XImage suggestion 3: pana9600x-pcr-reagent-bay.png - 4-8 °C PCR reagent bay of the PANA9600X during setup