Menu

Portable Gentier mini+ 16-Well Real-Time PCR System with 4 Fluorescence Channels

Quantity:
SKU: 0850927196
Model: Gentier mini+

{{ variable.name }}

{{ value.name }}

Gentier Mini Series / 16-Well qPCR

Portable Gentier mini+ 16-Well Real-Time PCR System with 4 Fluorescence Channels

A 3.2 kg real-time PCR platform for small laboratories, mobile laboratories and on-site testing. Four fluorescence channels, 1-16 sample throughput, and operation from a touchscreen, PC or Windows tablet.

1-16 samples per run4 fluorescence channelsAccuracy 0.1C or better3.2 kg portable body
Tianlong Gentier mini+ portable real-time PCR system instrument reference image
Gentier mini+ portable real-time PCR system, 205 x 156 x 153 mm and 3.2 kg.

Product Summary

The Gentier mini+ is a portable real-time PCR system from Tianlong's Gentier Mini Series, built for laboratories that run small sample batches and for teams that need to move qPCR testing outside a fixed lab bench. Each run accepts 1 to 16 samples, and four fluorescence channels allow multiplex detection in one tube. A fluorescence scan of all wells takes about 1 second.

Maximum heating rate is 5.0C/s or faster and maximum cooling rate is 4.0C/s or faster, with temperature control accuracy of 0.1C or better. The heated lid is adjustable from 40C to 110C. The instrument measures 205 x 156 x 153 mm and weighs 3.2 kg, and it accepts 0.2 mL transparent single tubes and 8-strip tubes. Operators can run it from the built-in touchscreen, a PC or a Windows tablet, using qualitative, quantitative, melting curve and SNP analysis modes.

Key Features

16-Well Small-Batch Runs

Throughput of 1-16 samples per run, so confirmations and low-volume panels do not wait for a full 96-well plate.

4 Fluorescence Channels

Four channels support multiplex assays in a single tube, and all wells are scanned in about 1 second.

Fast Thermal Ramping

Heating at 5.0C/s or faster and cooling at 4.0C/s or faster shortens protocol time, with 0.1C or better control accuracy.

3.2 kg Transportable Format

A 205 x 156 x 153 mm chassis at 3.2 kg lets the system move between rooms, vehicles and field stations.

Three Control Interfaces

Touchscreen, PC or Windows tablet control lets the bench or field team work the way it already does.

Four Analysis Modes

Qualitative, quantitative, melting curve and SNP analysis cover detection, quantification and genotyping workflows.

Technical Specifications

ModelGentier mini+
Product typePortable real-time PCR system / 16-well qPCR system
Throughput1-16 samples
Fluorescence channels4
Fluorescence scanning1 s for all wells
Maximum heating rate5.0C/s or faster
Maximum cooling rate4.0C/s or faster
Temperature control accuracy0.1C or better
Heated lid40-110C
Consumables0.2 mL transparent single tubes and 8-strip tubes
Dimensions (L x W x H)205 x 156 x 153 mm
Weight3.2 kg
Control optionsTouchscreen, PC, Windows tablet
Analysis modesQualitative, quantitative, melting curve, SNP
Typical applicationsMolecular diagnostics, mobile laboratories, on-site testing, biomedical research

Models and Options

The Gentier mini+ is the portable 16-well model within Tianlong's Gentier Mini Series; the wider Gentier family (X3, Sp96, 48 and 96 series) is documented separately. Within the mini+ model, buyers define three choices at order stage:

  • Control interface - touchscreen, PC or Windows tablet operation.
  • Consumable format - 0.2 mL transparent single tubes or 8-strip tubes.
  • Heated lid setpoint - any value inside the 40-110C range.

Materials and Structure

The system combines a 16-position sample block with a heated lid adjustable from 40C to 110C across the run window. An optical module reads four fluorescence channels and completes a full-well scan in about 1 second. The chassis measures 205 x 156 x 153 mm and weighs 3.2 kg, which is what makes relocation practical. The sample format is open within the supported range: 0.2 mL transparent single tubes and 8-strip tubes.

Applications

The Gentier mini+ is positioned for molecular diagnostics, mobile laboratories, on-site testing and biomedical research. Deployment environments reported for Tianlong molecular diagnostics projects include centres for disease control and prevention, clinical hospitals, inspection and quarantine stations, customs, research institutes, the livestock farming sector and blood banks.

Case Study

Representative deployment profile for Tianlong molecular diagnostics projects: client environments span centres for disease control and prevention, clinical hospitals, inspection and quarantine stations, customs, research institutes, the livestock sector and blood banks; project values range from US$50,000 to 200,000 over partnership periods of 3 to 5 years. Reported outcomes include customer satisfaction scores and a zero accident rate for projects, with detection accuracy, stable performance and compliance with international medical testing standards cited as highlights. Covered applications include disease diagnosis, clinical auxiliary diagnosis, companion diagnostics, health check-ups, screening for blood-borne infectious diseases, customs inspection and quarantine, and epidemiological analysis.

Customization

Configuration can be fixed before shipment around the control interface (touchscreen, PC or Windows tablet), the consumable format (0.2 mL transparent single tubes or 8-strip tubes) and the heated lid setpoint within 40-110C. If your workflow needs a particular control device, tube format or analysis mode combination, describe it in your inquiry so the Tianlong team can confirm availability for your order.

FAQ

How many samples can the Gentier mini+ run at once?

Throughput is 1 to 16 samples per run, which suits small batches, confirmations and low-volume panels.

Which tubes are compatible with the instrument?

The system accepts 0.2 mL transparent single tubes and 8-strip tubes.

Do I need to connect a computer to operate it?

No. The Gentier mini+ can be controlled from its touchscreen, from a PC or from a Windows tablet.

Which analysis modes are available?

Qualitative analysis, quantitative analysis, melting curve analysis and SNP analysis.

How fast are the thermal ramps and how tight is temperature control?

Maximum heating rate is 5.0C/s or faster, maximum cooling rate is 4.0C/s or faster, and temperature control accuracy is 0.1C or better.

What is the heated lid temperature range?

The heated lid is adjustable from 40C to 110C.

Is it suitable for a mobile laboratory or field testing?

The 205 x 156 x 153 mm, 3.2 kg format and touchscreen or tablet control are designed around small laboratories and on-site testing. Power supply and environmental operating conditions are not listed in this specification summary, so confirm them with the Tianlong team for your site.

How do I request price, MOQ and lead time?

Pricing, minimum order quantity and delivery schedule are quoted per configuration. Send your sample volume, control interface preference and consumable format to the contacts below for a quotation.

Inquiry Information

Email: inquiry@medtl.com

Telephone: +86-29-82682132

WhatsApp: +86 18182667606

Address: 4266 Shanglin Road, Xi'an 710021, China

Website: www.medtl.net

Image Filename and Alt Suggestions

  • gentier-mini-plus-portable-real-time-pcr-system-front.png - Alt: Gentier mini+ portable real-time PCR system, front view of the 16-well instrument
  • gentier-mini-plus-16-well-qpcr-system-side.png - Alt: Side profile of the Gentier mini+ 16-well qPCR system showing the compact chassis
  • gentier-mini-plus-touchscreen-control-panel.png - Alt: Touchscreen control panel used to operate the Gentier mini+ real-time PCR system
  • gentier-mini-plus-8-strip-tube-block.png - Alt: 8-strip tube sample block of the Gentier mini+ 16-well real-time PCR system